GasHook-UpInstrucons
Manual Gas
Valve (on/off)
Burner Assembly
Natural Gas Hook-Up
The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to
the appliance is the responsibility of the installer. Connect the inlet valve to rigid pipe, copper tube or an
approved exible metal connector, which complies with Z21.4/CSA 6.10. If using a gas hose (not supplied)
connect the ared end of the hose to the connector on the end of the inlet valve. Tighten using two
wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior to using the appliance. Piping
and valves upstream of the quick disconnect are not supplied. The gas supply pipe must be suciently
sized to supply the BTU/h specied on the rang plate, based on the length of the piping run. The quick
disconnect must not be installed in an upward direcon and a readily accessible manual shut-o valve
must be installed upstream of, and as close to, the quick disconnect as is feasible.
Purgethegassupplylineofanytrappedairpriortotherstringoftheunit.
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the appliance.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope
on any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be
subject to accidental damage.
Leak test all the connecons using a soap and water soluon as indicated in the diagrams.
Installaon
DO NOT USE AN OPEN FLAME.
WARNING!Whentheapplianceisbeingusedwiththeoponaltripod,itmustnotbesituatedon
acombusblesurface,norcanitbelocatedbelowacombusbleoverhang.
The log set and the burner assembly are shipped together.
Remove the gas log set and burner assembly and check for damage. DO NOT install damaged
components. The logs are fragile use care when handling.
Place the appliance on a level/secure surface in desired locaon. This locaon must be adjacent to the
gas supply line or cylinder.
NOTE: Minimum clearances to combusble construcon must be maintained, see "SPECIFICATIONS"
secon.
WARNING!Youmusthaveclearandeasyaccesstotheon/ovalveAFTERtheapplianceis
installedandconnectedtothegassupplyinordertosafelyturnotheburner.
THEON/OFFGASVALVEISUSEDTOTURNTHEBURNERONANDOFF.