Owner's Manual

www.napoleongrills.com
4
EN
Geng Started
1. Remove all of the parts from the carton. Use the parts list to ensure all necessary parts are included.
2. Do not destroy packaging unl the appliance has been installed and operates to your sasfacon.
3. Choose a locaon that meets the clearance to combusbles as outlined in this manual. Take into
consideraon the need for clear and easy access to the on/o valve AFTER the appliance is installed
and connected to the gas supply in order to safely turn o the burner.
4. Moststainlesssteelpartsaresuppliedwithaprotecveplasccoangthatmustberemovedprior
tousingtheappliance.Theprotecvecoanghasbeenremovedfromsomeofthepartsduringthe
manufacturingprocessandmayhavelebehindaresiduethatcanbeperceivedasscratchesor
blemishes.Toremovetheresidue,vigorouslywipethestainlesssteelinthesamedireconasthe
grain.
5. Read and follow all instrucons in this manual before installing or servicing this gas appliance.
Ifyouhaveanyquesonsaboutassemblyorapplianceoperaon,oriftherearedamagedormissing
partspleasecallourCustomerSoluonsDepartmentat1-866-820-8686between9AMand5PM
(EasternStandardTime).
WARNING!Thisapplianceisdesignedfornon-combusbleenclosuresonly,andmustbeinstalled
andservicedbyaqualiedinstallertolocalcodes.
GeneralInformaon
This gas appliance was tested and listed to Canadian and American Naonal Standards, ANSI Z21.97-2012
/ CSA 2.41-2012 “Standard for Outdoor Decorave Gas Appliance”. When an appliance is for connecon
to a xed piping system, the installaon must conform with local codes, or in the absence of local codes,
with the Naonal Fuel Gas Code, ANSI Z223.1/NFPA 54, Internaonal Fuel Gas Code, Natural Gas and
Propane Installaon Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, as applicable.
This appliance should be installed and serviced by a qualied installer to conform with local codes.
Installaon pracces vary from region to region and it is important to know the specics that apply to your
area, for example: in Massachuses State:
The appliance o valve must be a “T” handle gas cock.
The exible connector must not be longer than 36 inches.
The appliance and its individual shut o valve must be disconnected from the gas supply piping system
during any pressure tesng of the system at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut o
valve during any pressure tesng of the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5kPa).
The following clearances to combusble materials must be maintained:
Sides (all around) - 24 inches (610mm)
Top - 72 inches (1830mm)
Always keep the appliance area clear and free from combusble materials, gasoline, and other
ammable vapours and liquids.
Do not locate appliance where it can get
excessively wet.
Do not use this appliance if any part has been
under water. Immediately call a qualied
service technician to inspect the unit and to
replace any part of the control system and any
gas control, which has been underwater.