Installation Guide
W415-1329 / 06.25.14
55
EN
Main burner and
pilot cycles on
and off.
Venting is spilling. - Test with spill switch bypassed. Replace if defective.
- Check for vent blockage.
42.3_3
SYMPTOM PROBLEM TEST SOLUTION
White / grey fi lm forms. Sulphur from fuel is being
deposited on glass, logs or
combustion chamber surfaces.
- Clean the glass with a recommended gas appliance
glass cleaner.
- DO NOT CLEAN GLASS WHEN HOT.
- If deposits are not cleaned off regularly, the glass may
become permanently marked.
Exhaust fumes smelled in
room, headaches.
Appliance is spilling. - Ensure exhaust bracket gasket seal.
- Check door seal and relief fl ap seal.
- Check for chimney blockage.
- Check that chimney is installed to building code.
- Room is in negative pressure; increase fresh air supply.
- Check cap gasket on the fl ue pipe assembly.
Remote wall switch is in
’OFF’ position; main burner
comes on when gas knob
is turned to ‘ON’ position.
Wall switch is mounted upside down.
- Reverse.
Remote wall switch is grounding.
- Replace.
Remote wall switch wire is grounding.
- Check for ground (short); repair ground or replace wire.
Faulty valve. - Replace.