Oakville X4 Specification Sheet
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com
OAKVILLE™ X4 GAS INSERT
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
Minimum Mantel Clearances
Combustible mantel clearance can vary according to the mantel
depth. Use the graph to help evaluate the clearance needed. These
same requirements apply to any combustibles protruding on either
side of the appliance.
H
D
F
G
MANTEL DEPTH
0” (mm)
+
(
,
*
+
7
0
$
1
7
(
/
E
C
B
A
D
A
B
C
6” (152mm) MANTEL
F
H
G
24
1
/
4
” (61.6cm)
MANTEL DIMENSIONS
A
15" (38.1cm)
B
14" (35.5cm)
C
13" (33cm)
D
12" (30.5cm)
E
6" (152mm)
F
5" (127mm)
G
4" (102mm)
H
3" (76mm)
23 11/16" (60.1cm)
W415-1947 / E / 10.24.19
Minimum Clearance to Combustibles
This appliance must be recessed into a vented
non-combustible wood-burning appliance (prefab-
ricated or masonry) only. The minimum appliance
opening size in which the appliance is to be installed is:
• HEIGHT 24 3/4" (62.8cm)
• WIDTH 34 5/16" (87.1cm)
• DEPTH 18 1/4" (46.3cm)
The minimum allowable chimney fl ue size is 6"
(152mm) round.
The minimum distance, from the bottom of a
combustible mantel projecting 3" (76mm) maxi-
mum from the wall to the top of the appliance, is
12" (30.5cm) (see "minimum mantel clearances"
section).
Dimensions
front view
24
9
16
"
624mm
17
3
4
"
451mm
33
3
4
"
858mm
25
3
8
"
645mm
26
11
16
"
677mm
3"
2 PLS
23
11
16
"
601mm
16
9
16
"
421mm
8
"
204mm
16
1
2
"
419mm
5
1
2
"
139mm
SAFETY
BARRIER
right side view
top view
back view