INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 1278 CSA STANDARD EF30 ELECTRIC FIREPLACE CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
TABLE OF CONTENTS 1.0 2.0 3.0 INTRODUCTION 3 1.1 1.2 1.3 4 4 5 LOCATING APPLIANCE 6 2.1 2.2 6 7 6.0 8.0 9.0 10.0 11.0 MINIMUM CLEARANCE TO COMBUSTIBLES MINIMUM MANTEL CLEARANCES NEW CONSTRUCTION OR RENOVATION INSTALLING THE APPLIANCE THERMOSTAT AND THERMAL SENSOR INSTALLATION HARD-WIRE INSTALLATION 8 9 9 10 10 10 11 FRAMING FINISHING 13 14 5.1 5.2 5.3 14 14 14 HEARTH COLD CLIMATE INSTALLATION FINISHING CHECKLIST OPERATING INSTRUCTIONS 6.1 7.
1.0 INTRODUCTION ! • • • • • • • • • • • • • • • • • • • • • • • • • • • • • WARNING THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fire or injury. Risk of burns. Power to the appliance should be turned off and the appliance allowed to cool before servicing.
1.1 DIMENSIONS Heater vents - DO NOT COVER 10 1/4” 32 1/4” 30 3/8” 26 1/2” 11” 30” Rating Plate & Serial Number Power Cord and Thermostat ! WARNING HEATER VENTS AND AIR OPENINGS CAN NOT BE COVERED IN ANY CIRCUMSTANCES. 1.2 LISTING APPROVALS This appliance has been tested in accordance with the CSA Standards for fixed and location-dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer.
1.3 GENERAL INSTRUCTIONS ! WARNING READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THEM COULD CAUSE AN APPLIANCE MALFUNCTION RESULTING IN SERIOUS INJURY AND/OR PROPERTY DAMAGE. ALL ELECTRIC APPLIANCES HAVE HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE PRESENT. THIS ELECTRIC APPLIANCES IS TESTED AND LISTED FOR USE ONLY WITH THE OPTIONAL ACCESSORIES LISTED IN THESE INSTRUCTIONS.
2.0 LOCATING APPLIANCE ! WARNING DUE TO HIGH TEMPERATURES, THIS ELECTRIC APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC. KEEP COMBUSTIBLE MATERIALS SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS, CLOTHES AND CURTAINS AT LEAST 3 FEET (0.9M) FROM THE FRONT OF THE APPLIANCE. NEVER LOCATE THIS ELECTRIC APPLIANCE WHERE IT MAY FALL INTO A BATHTUB OR OTHER WATER CONTAINER. WEAR SAFETY GLOVES AND SAFETY GLASSES FOR PROTECTION DURING INSTALLATION AND MAINTENANCE.
2.2 GROUNDING APPLIANCE This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as shown in (C) is available for connecting three-blade grounding type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available. To disconnect appliance, turn controls to off, then remove plug from outlet.
3.0 INSTALLATION ! WARNING RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE CORD TO AVOID TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY. DO NOT RUN CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW RUGS, RUNNERS OR THE LIKE. ARRANGE CORD AWAY FROM TRAFFIC AREAS AND WHERE IT WILL NOT BE TRIPPED OVER. RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY MANNER.
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES ! WARNING THIS APPLIANCE MUST REMAIN REMOVABLE FROM THE ENCLOSURE. THE APPLIANCE MAY BE HARD WIRED, BUT IT IS RECOMMENDED THAT IT BE PLUGGED INTO A STANDARD OUTLET USING THE SUPPLIED POWER CORD. THIS APPLIANCE MUST NOT BE SEALED AROUND THE FRONT FACING. APPLIANCE VENTS LOCATED ON THE FRONT AND BACK OF THIS ELECTRIC APPLIANCE CANNOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE HAZARD. Sides, back, top 3.
3.3 3.4 3.5 NEW CONSTRUCTION OR RENOVATION A. Select a location that is not prone to moisture and is located at least 0.9 m or 3 feet away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc. B. Place the appliance in selected location to see how it will look in the future. C. Mark the desired location on the floor and store appliance in a safe, dry and dust free location. D. Frame in an opening leaving at least 1/4" (6 mm) around the edge of the appliance.
3.6 HARD-WIRE INSTALLATION ! WARNING ENSURE ALL POWER IS TURNED OFF BEFORE HARD WIRING THIS APPLIANCE. HARD WIRING CONNECTION If it is necessary to hard wire this appliance, a qualified electrician may remove the cord connection, and wire the appliance directly to the house hold wiring. This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the absence of local codes, use the current CSA C22.
2 35W ~ HEATER 1 HEATER 2 FLAME MOTOR 2 35W BLOWER MOTOR 1-1 10-10 M ~ M PTC 12-12 8-8 t105! 3-3 2-2 9-9 TEMPERATURE CONTROL SWITCH k+ -RG 2 t [ RE FIRE LAMP FI 10-10 MAIN CONTROL SIP2 REMO. TEM. t 1 TEMPERATURE SENSOR W415-0675 / C / 04.18.11 IF YOU USE THE TEMPERATURE SENSOR.PLS CHOOSE 1 RECEIVER 6-6 7-7 IF YOU PUT IN THE TEMPERATURE SENSOR ON THE WALL.
4.0 FRAMING ! WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME. THIS WILL ENSURE THAT CLEARANCE TO COMBUSTIBLES IS MAINTAINED WITHIN THE CAVITY. DO NOT NOTCH THE FRAMING AROUND THE APPLIANCE STAND-OFFS.
5.0 FINISHING ! WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS REMOVED, CRACKED, BROKEN OR SCRATCHED. FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING. 5.1 HEARTH A hearth is NOT necessary but is recommended for aesthetic purposes. 5.
6.0 OPERATING INSTRUCTIONS The controls are located on the bottom right corner of the appliance. A. Plug in your electric appliance. B. Main ON/OFF Power Switch and LED: This switch is located on the right side of the control panel. The "|" indicates ON and "O" indicates OFF. When the appliance is first turned on, the default settings are as follows: - Ember bed: HIGH - Flame: HIGH - Appliance: OFF C. Temperature Control Button and LED: The Appliance LED is located to the right of the FLAME Button.
6.1 OPERATING BY REMOTE CONTROL Once the appliance has been plugged in to a grounded electrical outlet, it is ready to operate. A. Plug in your electric appliance. B. is at the ON position! The remote control will NOT Make sure the appliance's main power button work if the main Power button is at the OFF position. NOTE: Ensure the house circuit breakers for the power supply are turned on.
7.0 MAINTENANCE ! WARNING ALWAYS DISCONNECT THE POWER AND ALLOW THE ELECTRIC APPLIANCE TO COOL BEFORE PERFORMING ANY CLEANING, MAINTENANCE OR RELOCATION OF THIS ELECTRIC APPLIANCE. TURN CONTROLS TO OFF AND REMOVE PLUG FROM OUTLET OR TURN OFF THE HOUSE CIRCUIT BREAKER TO ELECTRIC APPLIANCE RECEPTACLE. DO NOT INSTALL REPLACEMENT BULBS THAT EXCEED SPECIFIED MAXIMUM WATTS. THE HALOGEN LIGHT BULBS IN YOUR UNIT CAN BECOME EXTREMELY HOT.
7.1 FLAME GENERATION LAMP REPLACEMENT A. B. Remove the 7 screws from the bottom half of the back of appliance illustrated. Remove back plate. BACK PLATE Locate the flame generation cylinder drum. It is constructed of two removable halves. They are two (2) matte black sheet metal pieces with holes in them, either of which can be removed from the appliance. Back View of Appliance C. Remove the screw as illustrated, that is used to secure the flame generation cylinder drum. D.
7.2 EMBER BED LAMP REPLACEMENT A. Remove the 7 screws from the bottom half of the back of appliance as illustrated. Remove back plate. B. Locate the ember bed lamps which are underneath the flame generation cylinder drum. C. Remove spring clip. Hold socket and pull out old lamp. D. Hold socket and push in new lamp (DO NOT exceed wattage or handle with bare hands). E. Repeat steps C and D for the second lamp. F.
8.0 REPLACEMENT PARTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
9.0 TROUBLE SHOOTING ! WARNING TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
10.0 WARRANTY NAPOLEON® electric appliances are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certificate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. Once assembled the complete appliance is thoroughly inspected by a qualified technician before packing to ensure that you , the customer, receive the quality product that you expect from NAPOLEON®.
11.0 SERVICE HISTORY 43.1 W415-0675 / C / 04.18.
12.0 NOTES 44.1 W415-0675 / C / 04.18.