Installation Instructions
WARNING!
• The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain access
to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools.
• The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to provide
shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot drippings. The
enclosure cannot be located directly below the grill.
• There must be a minimum clearance of 2 in (51 mm) between the oor of the LP-gas cylinder enclosure
and the ground.
• The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and the
connecons inspected and tested outside the cylinder enclosure. Any connecons that can be disturbed
when installing the cylinder in the enclosure must be accessible for tesng inside the enclosure.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this connector to the are ng on the end of the manifold. Connect the
other end of the connector to the gas piping. Ensure that the connector does not pass through a wall, oor,
ceiling or paron, and is protected from damage. Do not use hose to connect the unit. It must be connected
with rigid pipe, copper tube or an approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane Installaon Code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon.
WARNING!
WARNING!
DANGER!
CYLINDER SIZE OPENING A AREA OPENING B AREA
20 lb (9.1kg)
20in
2
(130cm
2
) 10in
2
(65cm
2
)
30 lb (13.6kg)
30in
2
(195cm
2
) 15in
2
(100cm
2
)
OPENING
A
OPENING
B
PARTITION TO ISOLATE
NON LOCKING DOOR