BUILT IN UNIVERSAL LIQUEFIED PETROLEUM GAS HOOK-UP: The piping up to the gas grill is the



O








BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:

within 127mm of the top of the enclosure. The opening must have a total free area of more than 200 cm
2
for a 9.1 kg cylinder.


2
for a 9.1 kg cylinder

WARNING!
The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without
the use of tools.
The enclosure for the ULPG-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot
drippings. The enclosure cannot be located directly below the grill.
The enclosure must be designed so that the ULPG-gas cylinder can be connected, disconnected and
the connecons inspected and tested outside the cylinder enclosure. Any connecons that can
be disturbed when installing the cylinder in the enclosure must be accessible for tesng inside the
enclosure.
CYLINDER SIZE OPENING A AREA OPENING B AREA

20 in
2

2
 10 in
2

2



2

2
 15 in
2

2

5” (127 mm)
MAXIMUM
1” (25.4 mm)
MAXIMUM
OPENING
A
OPENING
B
2” (51 mm)
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
34” (864 mm)
RECOMMENDED
5” (127 mm)