Installation Guide
W415-1696 / 10.12.16
16
EN
4.2 LOG/EMBER BED LED TESTING
Cycle through the brightness
settings by pushing the fl ame
button on the control panel
Unplug the appliance
(if hardwired, turn off circuit breaker)
To gain access to the PCB and
wire harness, refer to sections
5.0 - 5.4
Ensure the wires from log/ember bed LED are
not pinched, frayed, and are fi rmly connected
on the PCB and log/ember bed LED
(Figure 7)
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
Appliance is functioning accordingly.
Refer to sections 5.0 - 5.4 for part
reinstallation
Replace the PCB.
Refer to section 5.6
(Control Board Replacement)
Perform a continuity test of the wire harness
Place positive probe in the CN2- terminal with the black wire and keep the negative probe
in the connector with the black wire of the right log LED
Did it pass the
continuity test?
Replace the wire harness
Replace LEDs
(Refer to section 5.7)
Replace the ember bed LED
strip. Refer to section 5.7
(LED Replacement)
Replace the right log LED.
Refer to section 5.7
(LED Replacement)
Turn off appliance
(Control panel switch)
NOTE: THE VOLTAGE
READING WILL
CONSTANTLY
FLUCTUATE
Turn off appliance
(Control panel switch)
Turn off appliance
(Control panel switch)
Turn off appliance
(Control panel switch)
Set multimeter to read
DC voltage
Place positive probe in the
CN2+ terminal with the red wire
(Figure 8)
Keep positive probe in the
CN2+ terminal with the red wire
Keep positive probe in the
CN2+ terminal with the red wire
Keep positive probe in the
CN2+ terminal with the red wire
Place negative probe in the
CN2- terminal with the black wire
(Figure 8)
Place the negative probe into the
connector with the black wire of
the ember bed LED strip (Figure 9)
Place the negative probe into the
connector with the black wire of
the left log LED (Figure 9)
Place the negative probe into the
connector with the black wire of
the right log LED (Figure 9)
Turn appliance on
(Control panel switch)
Turn appliance on
(Control panel switch)
Turn appliance on
(Control panel switch)
Turn appliance on
(Control panel switch)
Is the voltage reading
within 8V - 12V DC?
Is the voltage reading
within 5V - 7V DC?
Is the voltage reading
within 7V - 9V DC?
Is the voltage reading
within 9V - 12V DC?
Plug in the appliance
(if hardwired, turn on circuit breaker)
Are the log/ember LEDs
working?
START HERE
Turn off appliance
(Control panel switch)
Replace the left log LED.
Refer to section 5.7
(LED Replacement)