$10.00 W415-0638 / 04.24.08 W415-0638 / 04.24.
TABLE of CONTENTS PG 2-4 INTRODUCTION 7 Warranty General Information 5 Log Placement 8 SPECIFICATIONS Dimensions Input Gas Inlet Pressures Minimum Clearance to Combustibles 6-7 FINISHING OPERATION Operating Instructions Maintenance 9 MAINTENANCE High Elevation Installation 10-11 REPLACEMENTS INSTALLATION Natural Gas Propane Enclosures for LP Gas Supply Systems Tank Retaining Bracket Ordering Replacement Parts Replacement Parts PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE WARNING • DO NOT
NAPOLEON® gas appliances are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
GENERAL INFORMATION THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, for example: in Massachusetts State: • The appliance off valve must be a “T” handle gas cock. • The flexible connector must not be longer than 36 inches.
SPECIFICATIONS DIMENSIONS INPUT Model Fuel GPFN GPFP Natural Gas Propane Gas Max. Input Btu/Hr 60,000 60,000 GAS INLET PRESSURES Minimum Inlet Pressure Maximum Inlet Pressure Natural 4.5" w.c. 14.0"w.c LP (Propane) 11.0" w.c. 14.0"w.c. MINIMUM CLEARANCE TO COMBUSTIBLES Floor Side Walls Top of unit to ceiling Inches *0 24 72 mm *0 610 1.830 * WHEN THE PATIO FLAME IS BEING USED WITH THE OPTIONAL TRIPOD, IT MUST NOT BE SITUATED ON A COMBUSTIBLE SURFACE. W415-0638 / 04.24.
INSTALLATION The log set and the burner assembly are shipped together. Remove the gas log set and burner assembly and check for damage. DO NOT install damaged components. The logs are fragile use care when handling. Place the Patioflame on a level/secure surface in desired location. This location must be adjacent to the gas supply line or cylinder. NOTE: Minimum clearances to combustible construction must be maintained.
TANK RETAINING BRACKET #2 1. Fasten the bracket to the bottom of the propane bottle using bolt and nut supplied. (Fig. 1) 2. Tighten the lag screw into the mounting surface leaving approximately 1/4” of thread above the surface. 3. Slide propane bottle into position so that the bracket slides under the head of the lag screw. (Fig. 2) 4. Tighten the lag screw onto the bracket. 5. For fastening to a concrete surface a concrete anchor will be required. (Not Supplied) 3.
OPERATION Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting the burner, it will take a few seconds for the lines to purge themselves of this air. Once the purging is complete, the burner will light and operate as indicated in the instruction manual. Subsequent lighting of the appliance will not require such purging unless the gas supply has been disconnected.
MAINTENANCE 1. The appliance should be inspected before initial use and inspected and cleaned at least annually by a qualified field service person. 2. Tampering is DANGEROUS and voids all warranties. Any component that is found to be faulty, must be replaced with an approved component. 3. To obtain proper operation, it is imperative that the burner flame characteristics are steady, not lifting or floating. Check the burner flame patterns with the figure below.
1. REPLACEMENTS Contact your Napoleon® dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. When ordering replacement parts always give the following information: FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. MODEL & SERIAL NUMBER OF APPLIANCE 2. INSTALLATION DATE OF APPLIANCE 3. PART NUMBER 4. DESCRIPTION OF PART 5.
W415-0638 / 04.24.
Date Dealer Name W415-0638 / 04.24.08 Service Technician Name Service Performed This appliance must be serviced annually depending on usage.