Hand ghten clockwise. Do not use tools. Leak test all joints prior to using the grill. A leak test must be
performed annually and each me a cylinder is hooked up or if a part of the gas system is replaced. If this
grill is to be connected directly to a house propane gas supply line, follow the instrucons for the natural
gas hook-up. Ensure that the supply pressure is 11 inches water column.
Natural Gas Hook-Up: These connecons must be made by a licensed gas er. This natural gas grill is
supplied with a gas supply hose (complete with a quick disconnect) designed for natural gas and cered
for outdoor use. The gas grill is designed to operate at an inlet pressure of 7 inches water column. Piping
and valves upstream of the quick disconnect are not supplied. The installaon must comply with CAN
B149.1 Natural Gas and Propane installaon code in Canada, or to the Naonal Fuel Gas Code, ANSI
Z223.1 in the United States. The gas supply pipe must be suciently sized to supply the BTU/h specied
on the rang plate, based on the length of the piping run.
The quick disconnect must not be installed in an upward direcon and a readily accessible
manual shut-o
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The ared end of
the hose must be connected to the ng on the end of the manifold tube or ex tube (if applicable) as
illustrated in the Natural Gas Hose Aachment diagram. Tighten using two wrenches. (Do not use thread
sealer/pipe dope.) Leak test all joints prior to using the gas grill.
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the grill.
Do not route hose underneath the drip pan.
Do not route hose between boom shelf space and back panel.
Do not route hose over top of rear panel.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe
dope on any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons
found in the manual.
The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the
gas supply piping system during any pressure tesng of that system at test pressures in excess of 0.5
psi (3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shuto valve during any pressure tesng of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).
!