User's Manual
15
GARAGE DOOR CONTROL / SPECIAL APPLICATIONS
Gemini Relay Control Group Support
When used on a Gemini series control which supports Relay Control Groups (GEM-P3200 & P9600), each time the
KeyFob is used to activate Relay 1 or Relay 2, Relay Control groups 1 & 2 are also simultaneously activated, allowing
control of external (RB3008) relays and/or X-10 devices connected to the control panel.
Press [
∗
] to momentarily activate
Relay 3 to open a garage door.
COM
N/O
N/C
14
15 16
Garage door opener wall mounted
push-button, or normally open
garage door opener input.
Relay 3 Garage Door
Control
Lighting or other special
application device.
Press [ON/OFF] and [
∗
]
simultaneously to toggle
Relay 1 On / Off
COM
8
N/O
N/C
9 10
+
-
Relay 1 Appliance
Control
+ Low
Voltage
Hold Down [
∗
] for 2 seconds to
toggle Relay 2 On / Off
COM
11
N/O
N/C
12 13
Lighting or other special
application device.
+
-
Relay 2 Appliance
Control
+ Low
Voltage
Hold Down [
∗
] for 2 sec. to
momentarily activate Relay 2 to
open a second garage door.
COM
N/O
N/C
11
12 13
Garage door opener wall mounted
push-button, or normally open
garage door opener input.
Relay 2 Second Garage
Door Control
Install Jumper
across Config
Pins J6
J6
Bus Mode Operation
When installed on the bus of a Gemini or Ademco control panel, receiver Relays 1 and 2 are available for other applications
such as lighting or appliance control, while Relay 3 remains dedicated to the control of a garage door opener.
•
Press [ON/OFF] and [
∗
] simultaneously to toggle Relay 1 On / Off
•
Hold Down [
∗
] for 2 seconds to toggle Relay 2 On / Off
OR
•
Hold Down [
∗
] for 2 sec. to momentarily activate Relay 2 to open a second garage door.
(Install Jumper 6 - Relay 2 momentary).
2WAY-UNIVKF_WI1024J.19_I...
page 15
Friday, February 13, 2004 08:57
Composite