Certification

GF9 10/04
December 1, 2009
Certification No: CTC 9730
Attention: Benjamin Coley
Plasticase
1059, boul. des Entreprises Ouest
Terrebonne, QC Canada
J6Y 1V2
Reference: a. ATA 300
b. ASTM D4169
TESTING CERT #2582.01
c. Mil-Std-810F
d. CEI/IEC 60529:2001
e. PO# 761505
f. Quote CTQ 7933
g. Cascade TEK Job No. 9730
CERTIFICATION
Cascade Technical Sciences hereby certifies that Fourteen (14) Nanuk Protective Cases,
(With Custom Foam) P/N 905-0006 S/N 2, P/N 915-0006 S/N 2A, P/N 920-0006 S/N 2B & 2C,
P/N 930-0006 S/N 2D, P/N 940-0006 S/N 2E and P/N 945-0006 S/N 2F and (With Foam) P/N
905-0006 S/N 1, P/N 915-0006 S/N 1A, P/N 920-0006 S/N 1B & 1C, P/N 925-0006 S/N 1D,
P/N 940-0006 S/N 1E and P/N 945-0006 S/N 1F were subjected to the following tests:
1. Impact Resistance Test per Reference (a) and (f) Item 1, samples were exposed to
impact using a bar weighing 13.2lbs with a hemispherical end of 3.2cm. Bar was
dropped with its longitudinal axis vertical onto each sample’s weakest point from a
height of 0.5m. Samples were conditioned to a temperature of -20°C before impact
exposure. (Custom Foam).
2. Schedule A Handling Test per Reference (b) Paragraph 10.2.3 and (f) Item 2,
samples were exposed to drops from heights depending on each sample weight per
specification. Samples were conditioned at lab ambient conditions and then
temperature of -28°C and +60°C for a minimum of 3 hours at each condition.
(Custom Foam).
3. Schedule F Loose Load Vibration Test per Reference (b) Paragraph 13.1 and (f)
Item 3, samples were exposed to repetitive shock for 30 minutes along the normal
shipping axis and the remaining 30 minutes distributed among all other shipping
orientations. (Custom Foam).
4. Schedule H Environmental Hazard Rainfall Test per Reference (b) Paragraph 15.2
and (f) Item 4, samples were exposed to temperature cycling and water spray test
per method D951 and test level per assurance level 1. (Custom Foam).
5. Immersion Test per Reference (c) Method 512.4, Procedure I and (f) Item 5,
samples were conditioned 10°C above water temperature and then immersed in 3ft.
of water for a period of 30 minutes. (Foam) *
Cascade Technical Sciences
5245-A NE Elam Young Pkwy
Hillsboro OR, 97124
Phone: (503) 648-1818
Fax: (503) 648-1798
www.cascadetek.com