User's Manual
Table Of Contents
- Software specifications
- Software features
- Software functions
- 1.Introduction to “Register” and “Sign in” functions
- 2.Introduction to “Measuring ” function
- 3.Introduction to a real-time ECG waveform diagram
- 3.Introduction to “End Measurement” function
- 4.Introduction to “Data Uploading” function
- 5.Introduction to “Measurement Records” function
- 6.Introduction to “User Profile” function
- 7.Introduction of “Playback ECG” function
- 8.Introduction of online customer service function
- 9.Set Sign-in password
12
Warning: This operation will discard any measurement data that didn’t
upload last time, so it is not recommended to use this under normal
circumstances.
3.3.9 Disposable ECG electrodes
After a measurement session is completed, please detach the device first, then remove
the disposable electrodes from your body. Please do not throw the electrodes as trash, but
recycle it according to the medical device recycling standards instead.
3.3.10 Device shutdown
When measurement is completed and all data has been uploaded, please remove the battery
from the device to shut it down.
3.3.11 Viewing historical dataAll measurement data properly uploaded can be viewed from
the app. You can view the measurement data at any time point, and provide the data to
medical professionals for further diagnosis.
Start the app, tap the “skip connection” button, then tap the “Records” menu to
wselect the desired measurement record, and drag the scroll bar to view the ECG data at any
time point.
3.3.12 Uninstall the smartphone app
If you need to uninstall the app, you can do so via Android’s “system settings”-
“applications” menu, find the app in the menu and select “uninstall”.
Warning: Uninstalling the app does not cause the loss of historical measurement data.
4、Auxiliary functions
4.1 Indicator lights and meaning:
Meaning
Light state
The device is powered up, no measurement
in-progress
Steady green light
Measurement in-progress
Green light flashes every 5 seconds
After press and hold the device button for 4
seconds, the device is restarting
Blinking Green light
4.2 Replacing consumables
(The disposable ECG electrodes are consumables that should be disposed after use, and
should not be reused.
(The disposable ECG electrodes are disposable consumables, customers are advised to
purchase products with valid medical device registration certificates from trusted sources,
alternatively you could also purchase by contacting our company directly.)
4.3 Replacing the battery
This device uses one non-rechargeable CR2032 cell battery.
The device is designed for continuous use. We recommend replacing the battery with a
new one after each use.
Batteries should be purchased from trusted sources to ensure stable voltage and
measurement quality.
4.4 Handling the Product
Do not treat the device and its accessories as ordinary domestic waste. In the end
stage, they shall be treated according to the requirements of medical device standards. Do
not discard them at will.