Specifications

Nanjing Ningyuan Intelligent Instrument Co., Ltd RM-RF10TP-1278
Address: Building 6, Jima Industrial Park, No. 669 Jiangjun Avenue, Jiangning District, Nanjing, Jiangsu, China
14
/ 16
4.5.6 Reset(0x03)
Name of
name
Data Head
Command
code
Data
domain
Package tail
Symbol
Head
Cmd
Data
End
bytes
1
1
0
1
Value
0x68
0x03
0x16
Module received in configuration mode: [0x68 0x03 0x16] command frame is automatically
restarted and the device parameter information [0x22]. is returned after the restart is successful.
4.5.7 Echo Control(0x04)
Name of
name
Data Head
Command
code
Data
domain
Package tail
Symbol
Head
Cmd
Data
End
bytes
1
1
0
1
Value
0x68
0x04
0x16
Data domain(Data)
Name of
name
Echo type
Symbol
Type
bytes
1
Echo type: Type: Set the flag bit to open or close the echo, HEX code 1 byte.
Echo type 1: [0x00]: turn off the echo, will no longer reply to the settings command, but
directly effective.
Echo type 2: [0x01]: Turn on the echo and will reply to all setup commands.
4.5.8 Read Information(0x11)
Name of
name
Data Head
Command
code
Data
domain
Package tail
Symbol
Head
Cmd
Data
End
bytes
1
1
0
1
Value
0x68
x11 0
0x16
Module received in configuration mode: [0x68 0x11 0x16] , Returns device information [0x12],
after command frame.
4.5.9 Module Information(0x12)
Name of
name
Data Head
Command
code
Data
domain
Package tail
Symbol
Head
Cmd
Data
End
bytes
1
1
4
1
Value
0x68
0x12
0x16
Data domain(Data)