Specifications
Table Of Contents
Nanjing Ningyuan Intelligent Instrument Co., Ltd RM-RF10TP-1278
Address: Building 6, Jima Industrial Park, No. 669 Jiangjun Avenue, Jiangning District, Nanjing, Jiangsu, China
13
/ 16
Values
0x00
0x01
0x02
0x03
0x04
0x05
Rate
0.9 Kbps
1.8 Kbps
3.5 Kbps
7.0 Kbps
Values
0x06
0x07
0x08
0x09
Channel: Channel: module communication channel, Hex code 1 byte.
The different channel modules will automatically use different communication frequencies:
RM-RF10TP-1278(PI) , RM-RF10TP-1278(C) : 433 MHz~509 MHz;
RM-RF10TP-1278(E) , RM-RF10TP-1278(N) : 850MHz~930 MHz;
The corresponding frequency band of the wireless communication channel refers to Annex 1:
Corresponding Frequency of the Channel.
Device type: Type: the type of the current device, Hex code 2 bytes.
Device type 1: [0x01 0x02]: RM-RF10TP-1278(PI) transmission module;
Device Type 2: [0x01 0x03]: RM-RF10TP-1278(C) transmission module;
Device Type 3: [0x01 0x04]: RM-RF10TP-1278(E) transmission module;
Device Type 4: [0x01 0x05]: RM-RF10TP-1278(N) transmission module.
Firmware version: Ver.: firmware version of the current device, Hex code 2 bytes.
Example: Firmware version: [00x01 0x09]: The current firmware version 1.09
4.5.4 Response Test(0x01)
Name of
name
Data Head
Command
code
Data
domain
Package tail
Symbol
Head
Cmd
Data
End
bytes
1
1
0
1
Value
0x68
0x01
0x16
Module received in configuration mode: [0x68 0x01 0x16] Returns device parameter information
[0x22]command frame.
4.5.5 Restore Factory(0x02)
Name of
name
Data Head
Command
code
Data
domain
Package tail
Symbol
Head
Cmd
Data
End
bytes
1
1
0
1
Value
0x68
0x02
0x16
Module received in configuration mode: [0x68 0x02 0x16] command frame, all parameters are
reset to factory status and the recovered device parameter information [0x22], is returned.
Note: factory default equipment parameter information is:
Device address: [0x00 0x01]: 1;
Wireless rate: [0x07]: 1.8Kbps;
Channel: [0x00]: 0 channel 433 MHz communication band.