Datasheet
SPECIFICATION PAGE
TACT SWITCH 3 / 4
6. WEATHER PROOF
TEST CONDITIONS
6.1
6.2
6.3
6.4
APPD CHKD DSGN TITLE
DOCUMENT NO.
ZONESYMBDATEAPPDCHKDDSGD
Cold
heat proof
After testing at -30℃ for 96hours, the sample is
allowed to stand under normal temperature and
humidity conditions for 1hour and measurement
is performed within 1hour after that.
Water drops should be wiped off.
After test at 60±2℃ and 90 ~ 95% in relative
humidity for 96hours, the sample is allowed to
stand under normal temperature and humidity
conditions for 1hour, and measurement is
performed within 1hour after that.
Water drops should be wiped off.
PROPERTY PERFORMANCE
* The requirement in
item 3 and 4 shall
be satisfied.
Dry
heat proof
After testing at 85℃ for 96hours, the sample is
allowed to stand under normal temperature for
1hour and measurement is performed within
1hour after that.
; After the test conducted under 5 cycles the
sample is allowed to stand under normal
temperature and humidity conditions for
1hour, and the measurement is performed
within 1hour.
Damp
heat proof
Thermal
cycling
* The requirement in
item 3 and 4 shall
be met.
JT 0102LF
* Insulation resistance :
10㏁ minimum.
* Dielectric strength :
same as item 3.4.
* Contact resistance :
same as item 3.2.
+65℃
-10℃
2H
2H 1H
1H
1 cycle
PDF created with pdfFactory Pro trial version www.pdffactory.com