Datasheet

SPECIFICATION PAGE
TACT SWITCH 1 / 4
1. GENERAL
1.1 Application : This specification is applied to low current circuit tactile switch
for electronic equipment.
1.2 Operating temperature range : -20 ~ 70, 45 ~ 85% RH
1.3 Storage temperature range : -30 ~ 80. However, 96 hours maximum for continuous
storage over a range -20 ~ -30 and a range 70 ~ 80.
1.4 Test conditions : The standard test conditions shall be 5 ~ 35 in temperature,
45 ~ 85% RH and 860 ~ 1060mbar in atmospheric pressure.
Should any doubt arise in judgement, tests shall be conducted
at 20±2, 65±5% RH and 860 ~ 1060mbar.
2. RATED VOLTAGE AND CURRENT.
DC 12V 50
3. ELECTRICAL PERFORMANCE
TEST CONDITIONS
Contact
arrangement
Contact Measured at DC 5V 100mA or by ohmmeter allowing
resistance a small current at 1 with a load of twice
of the Actuating force.
3.3
3.4
3.5
APPD CHKD DSGN TITLE
DOCUMENT NO.
ZONESYMBDATEAPPDCHKDDSGD
3.1
3.2
* No insulation defect
shall be observed.
* less than 5 msec.
* 1 pole, 1 throw.
Measured by lightly striking the center of the
button stem at a rate of 3 operations/sec
Insulation
resistance
PROPERTY
DC 100V is applied between terminals and
between terminals and cover for 1minute
±5seconds.
AC 250V (50 ~ 60)is applied between terminals
and between terminals and cover for 1 minute.
JT 0102LF
PERFORMANCE
* greater than 100.
* less than 50m.
Bounce
Dielectric
strength
PDF created with pdfFactory Pro trial version www.pdffactory.com