U-1000 Series 1000 Channel PLL Frequency Synthesized UHF Wireless Microphone and Instrument System nady.
TABLE OF CONTENTS INTRODUCTION ................................................................................................2 SYSTEM FEATURES..........................................................................................3 OPERATING INSTRUCTIONS ..........................................................................4 U-1000, U-2000 Receiver ................................................................................5 UH-1000 Handheld Transmitter ..........................................
ACCESSORIES PART NUMBER DESCRIPTION 3008-11 ............USB cable (included w/each Rx) 3008-10 ............Audio cable 1/4” to 1/4” mono plug (included w/each Rx) 12017-50 ..........WMC-11 Rubber mic clip for handheld wireless microphone (included w/each UH-1000) Adapters (one included w/each Rx) 3007-98 ..............Power Supply, 115VAC for U-1000 Rx 3008-00 ..............Power Supply, 230VAC for U-1000 Rx 3007-99 ..............Power Supply, 115VAC for U-2000 Rx 3008-01 ..............
OPERATING INSTRUCTIONS SPECIFICATIONS U-1000, U-2000 Receiver For best operation, the receiver should be placed at least 1 meter above the ground and 1 meter away from a wall or metal surfaces. The transmitter should also be at least 1 meter away from the receiver. Keep antennas away from noise source such as motors, automobiles, neon light, signal processors, computer, as well as large metal objects.
SPECIFICATIONS OPERATING INSTRUCTIONS U-1000, U-2000 Receiver SYSTEM SPECIFICATIONS Operating Frequency Range ....................1000 channels switchable Freq. Synthesized ......................................PLL system with frequency stability <0.005% Frequency Response ................................30 HZ-15 KHZ ±3 dB Dynamic Range..........................................120 dB Harmonic Distortions ................................<0.5% Modulation..................................................
OPERATING INSTRUCTIONS TIPS U-1000, U-2000 Receiver next location. After finishing the edit hold the SET (7) button until the curser stops blinking. 4. Group and Channel (Preset) Choose the UHF-1000 operating frequency by selecting one of the 24 Groups and one of the 40 Channels in each group. The first two top digits on the left are the Group and the second top two digits to the right are the Channel. CF: 01 - 01 RF AF In the Group and Channel Menu, hold the SET (7) button for 3 seconds.
SYSTEM OPERATION (Note: The UH transmitter CAP (7) must be removed before installing the USB cable.) (Note: Only one transmitter can be used with one UHF-1000 receiver. It is not possible to use two transmitters on the same frequency and mix the output of these transmitters into one wireless receiver. If you have any questions, please contact the Nady Systems Customer Service Department. See SERVICE section, pg. 21.) CAUTIONS AND TROUBLESHOOTING Feedback Observe care in selecting P.A.
OPERATING INSTRUCTIONS SYSTEM OPERATION UH-1000 Handheld Microphone Connecting Audio Output There are two audio outputs on the back of the receiver. Mic-level balanced and Line-level unbalanced. Use shielded audio cable for the connection between the receiver and the mixer. If the mixer / amp is a 1/4” phone jack, connect a cable from the 1/4” unbalanced audio output from the receiver.
SYSTEM OPERATION Level adjustment UB-1000 Transmitter The input level has four choices. “1” is the lowest gain, and “4” is the highest. For instrument, lavalier mic, and HM-1 headset mic use the normal setting of “3”. For HM-1 use setting “1”. When ready to speak, move the audio MUTE switch to the OFF position. Adjust the volume of the receiver for optimum performance, a transmitter sensitivity control is provided.
OPERATING INSTRUCTIONS SYSTEM OPERATION UH-1000 Handheld Microphone 6. Sensitivity Set Level (Input level sensitivity) In input level sensitivity has four choices. “1” is lowest gain, and “4” is highest gain. SENS SET LEVEL [ 3 ] In the Sens Set Level Menu, hold the SET (8) button for 3 seconds. The curser will blink; press the UP (9) or DOWN (10) buttons to select 1 of 4 level setting. After finishing the edit hold the SET (8) button until the curser stops blinking. 7.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS UB-1000 Bodypack Transmitter UB-1000 Bodypack Transmitter 6. Sensitivity Set Level (Input level sensitivity) In input level sensitivity has four choices. “1” is lowest gain, and “4” is highest gain. SENS SET LEVEL [ 3 ] In the Sens Set Level Menu, hold the SET (10) button for 3 seconds. The curser will blink; press the UP (11) or DOWN (12) buttons to select 1 of 4 level setting.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS UB-1000 Bodypack Transmitter UB-1000 Bodypack Transmitter 2. “NADY UB-100” (can not be edited) 1 NADY UB-1000 3. User Name The User Name field has 8 character spaces. Choose from upper and lower case alphabet, 27 special characters (including space), and 10 numbers. USER NAME In the User Name Menu, hold the SET (10) button for 3 CF: 01 - 01 seconds.