Owner’s Manual DKW-Duo Dual Wireless Microphone System
Contents Introduction.............................................................................................................................. 2 System Features...................................................................................................................... 2 Operation.................................................................................................................................. 3 Specifications......................................................................
Operation Receiver 3. The 1/4” AUDIO OUTPUT JACK (5) provides a fixed, unbalanced MIC level audio output for connection to your mixer with the 1/4” to 1/4” cord supplied. As when making any connection, make sure the mixing board’s volume is at the minimum level before plugging in the receiver to avoid possible sound system damage. 1. Plug the AC/DC adapter (provided) into the 9VDC INPUT JACK (3) on the back of the receiver. Then plug the power supply into an AC outlet.
Handheld Microphone Transmitters 1. Unscrew the BATTERY COMPARTMENT COVER (8) and remove. Insert a fresh 9V BATTERY (9), observing correct polarity as marked, and screw the cover back on to the microphone. To ensure proper battery contact, the cover must be screwed on completely. 2. Turn on the handheld mic by sliding the OFF/ON SWITCH (10) to the “On” position. The BATTERY INDICATOR LED (11) will give a single quick flash, indicating usable battery strength.
Specifications Overall System Performance Frequency Response Dynamic Range Total Harmonic Distortion RF Carrier Frequency Range Frequency Stability Modulation Operating Range 80-14,000 Hz, +/-3dB 95dB <0.7% 170-216 MHz +/- 0.005%, crystal controlled FM (F3E), +/-15KHz max. 150 ft. typical-up to 300+ ft.
Service Information In the U.S. If you are experiencing operational problems with your system, please refer to the Support page at www.nady.com for assistance. Should your wireless system require service, please contact the Nady Service Department at (510) 652-2411 to obtain a Return Authorization (R/A) Number and service quote (if out of warranty). Make sure the R/A Number is clearly marked on the outside of the package that you are returning.
90-Days Limited Warranty Nady Systems, Inc. warrants to the original consumer purchaser (U.S.A. only) that the unit is free from any defects in material or workmanship for a period of 90 days from the date of original retail purchase. If any such defect is discovered within the warranty period, Nady Systems, Inc. will repair or replace the unit free of charge, subject to verification of the defect or malfunction upon return to Nady Systems.
6701 Shellmound Street | Emeryville, CA USA 94608 T 510.652.2411 | F 510.652.5075 | www.nady.