consumption NADAMOO User Guide This User Guide Applies to E3000(H) (E3100(H)) 第 1 页 共 50 页 V1.1.
About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service. The pictures in this user guide are for reference only. If there are any pictures which not match the actual product, please take actual products as the standard.
V0.1.0 Output all product information by setting the code 2016.01.27 V0.1.1 1D added to identify both bar codes at the same time 2016.03.25 V0.1.2 1. Communication mode added to support AUTO UK and AUTO UV V 2. DM add the multi-code reading mode 2016.05.06 V0.1.3 Add 2D code packet format description 2016.05.25 V0.1.4 2D code added to support Aztec Code, MaxiCode and Han Xin Code 2016.06.07 V0.1.5 Add the default configuration 4 2016.06.17 V1.0.0 Official version 2016.10.31 V1.0.
Catalog 1、Product Introduction.................................................................................................................................. 1 1.1 Main feature ...................................................................................................................................... 1 1.2 Unpack your device........................................................................................................................... 1 1.3Product display ............................
2.2.1 Reset to default configuration ................................................................................................ 8 2.2.2 Communication mode setting................................................................................................. 8 2.2.3 Decode scanning time setting ................................................................................................ 9 2.2.4 trigger mode setting ...................................................................................
2.3.8 positioning lamp setting .........................................................................................................15 2.4 Enable\Disable decode function ......................................................................................................15 2.4.1 code system character output ...............................................................................................15 2.4.2 Enable/Disable UPC-A .........................................................................
2.4.21 Enable/Disable QR ..............................................................................................................20 2.4.22 Enable/Disable single/double QR .......................................................................................20 2.4.23 Enable/Disable MicroQRCode ............................................................................................21 2.4.24 Enable/Disable Data Matrix(DM) ..............................................................................
3、Serial port instructions .............................................................................................................................27 3.1 Basic Configuration ..........................................................................................................................27 3.2 Volume and light setting...................................................................................................................28 3.3 Enable\Disable decode function ...........................
1、Product Introduction This user guide applies to E3000(H)(E3100(H)), which identify 1D&2D barcodes by 2D image scanning pattern. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed. In this chapter, we will introduce the instruction of scanner with pictures, please compare to the scanner you bought when reading this user guide, which is good for your understanding.
1.3 Product display 1.3.1 External view 1.3.2 Size(mm) 1.4 Interface description Product standard interfaces are: RS232 (DB9 orifice), TTL, USB Keyboard(USD HID), Keyboard and Wiegand. Standard interface of different products are not the same, please confirm before purchase, other interfaces can be customized according to customer needs.
1.5 Communication port Interface NO. Name Type Description 1 NC Empty Spare 2 VDD DC power supply DC3.3V 3 GND Digital ground GND 4 Rx Input Serial input port TTL level 5 Tx output Serial input port TTL level 6 USB_D- Input / output USB_D- signal 7 USB_D+ Input / output USB_D+ signal 8 NC Empty Spare 9 BPR output Buzzer output signal 10 LED output Indicator light output signal 11 NC Input Reset signal input, Active low.
1.6 Peripheral circuit diagram 1.6.1 buzzer 1.6.
1.6.3 LED 1.7 Communication port The scanner must be connected to a host to operate. Host can be a PC, POS machine, intelligent terminal with USB or RS-232 interface.
1.
1.10 Maintenance * The window must be kept clean, the supplier do not bear the guarantee responsibility due to the improper maintenance. * Avoid the window being wear and tear or scratched by hard object * Use the hairbrush to remove the stain on the window * Clean the window with a soft cloth, such as lens cleaning cloth * Spraying liquid onto the window is prohibited. * Prohibit any cleaning solvents, except for the cleaning water. 1.
Reset to default configuration 2、barcode setting Option and function setting mainly through reading a series of special barcodes. In this chapter, we will provide you a detailed introduction of the options and functions available for user setting, and the corresponding setup code. This method of setting the scanning is direct, easy to understand and user friendly. 2.1 Mark setting 1 Reset to default configuration 2 2.2 Setting barcodes 2.2.
Reset to default configuration 2.2.3 Decode scanning time setting This barcode is used to set the most longest decoding time in the range of 0.50 to 25.5 second when scanner reading barcode. First scan below barcode enter setting mode, then scan three numbers from the appendix. Use 0 to make up three numbers if the time you want to set less than three numbers. For example, you want to set 0.5 second as decode scanning time, you should scan “0””0””5” at the appendix. If you want to set 10.
Reset to default configuration Host trigger mode setting step: 1、wake up operation: Send 0x00 first, then send effective instruction after 50ms, (factory default is power saving mode ) 2、start scan:04 E4 04 00 FF 14 3、end scan:04 E5 04 00 FF 13 4、after end scan, scanner module time-out in 800ms without working remark: If you want to omit step 1 and 4, please change power mode to continuous power mode 2.2.
Reset to default configuration Enter TAB 2.2.8 Turn on/Turn off configuration code Enable Configuration Code Disable Configuration Code 2.2.9 Enable\Disable sending setting code Enable sending setting code Disable sending setting code 2.2.10 Power mode In power saving mode scanner module time-out after a period of time without working. In continuous power mode scanner module keep awake. Continuous power mode Power saving mode(default) 2.2.
Reset to default configuration high level:1, middle level:8, low level:15. Default: high level. Special sensitivity High sensitivity Middle sensitivity Low sensitivity 2.2.12 Invoice automatic identification and output (only for China) close(default) open 2.2.
Reset to default configuration 2.2.14 Invoice type (only for China) special invoice(default) Plain invoice 2.3 Volume and light setting 2.3.1 indicator light setting To set the meaning of the indicator light. Represent decode Represent power 2.3.2 Successful decode indicate setting If decode successfully the indicator light on for a while, on condition that the indicator light has been set to represent decode. Off On 2.3.
Reset to default configuration Volume-Middle Volume-High 2.3.4 Mute setting Turn on or off all volume Off On 2.3.5 Starting up sound setting off on 2.3.6 setting code volume Off On 2.3.
Reset to default configuration LED on when reading Always on Always off 2.3.8 positioning lamp setting Always on when reading Always on Always off 2.4 Enable\Disable decode function 2.4.1 code system character output On Off 2.4.
Reset to default configuration Disable 2.4.3 Enable/Disable UPC-E Enable Disable 2.4.4 Enable/Disable EAN-8 Enable Disable 2.4.5 Enable/Disable EAN-13 Enable Disable 2.4.
Reset to default configuration 2.4.7 Bookland EAN(ISBN) Bookland ISBN-10 Bookland ISBN-13 2.4.8 UPC/EAN Addendum Code Disable UPC/EAN Addendum Code Only identify UPC/EAN with addendum code Auto identify UPC/EAN Addendum code 2.4.9 Convert UPC-E TO UPC-A Enable Convert UPC-E to UPC-A Disable Convert UPC-E to UPC-A 2.4.
Reset to default configuration Disable 2.4.11 Enable/Disable GS1-128 Enable GS1-128 Disable GS1-128 2.4.12 Enable/Disable Code 39 Enable Code 39 Disable Code 39 2.4.13 Enable/Disable Code 93 Enable Code 93 Disable Code 93 2.4.
Reset to default configuration 2.4.15 Enable/Disable ITF25 Enable ITF25 Disable ITF25 2.4.16 Enable/Disable industrial ITF25 Enable industrial ITF25 Disable industrial ITF25 2.4.17 Enable/Disable Codabar Enable Codabar Disable Codabar 2.4.18 Enable/Disable MSI Enable MSI Disable MSI 2.4.
Reset to default configuration Disable GS1 DataBar(RSS) 14 2.4.20 Enable/Disable PDF417 Enable PDF417 Disable PDF417 2.4.21 Enable/Disable QR Enable QR Disable QR 2.4.
Reset to default configuration 2.4.23 Enable/Disable MicroQRCode Enable MicroQRCode Disable MicroQRCode 2.4.24 Enable/Disable Data Matrix(DM) Enable Data Matrix(DM) Disable Data Matrix(DM) 2.4.25 Enable/Disable Maxi Code Enable Maxi Code Disable Maxi Code 2.4.26 Enable/Disable Aztec Code Enable Aztec Code Disable Aztec Code 2.4.
Reset to default configuration Disable Chinese code 2.5 serial port communication setting 2.5.1 Baud rate setting Baud rate means the bit number transfer in each second. The baud rate of the scanner module must match with the receive-data host. If the baud rate doesn’t match the host, then the data might be wrong or can’t remote host. Baud rate 9600 Baud rate 19,200 Baud rate 38,400 Baud rate 57600 Baud rate 115200 2.5.
Reset to default configuration Even digital Choose MARK as Odd-even check bit and Odd-even check digital always is “1”. Mark Choose SPACE as Odd-even check bit and Odd-even check digital always is “0”. SPACE If you don’t need Odd-even check bit, choose null. Null odd-even check bit 2.5.3 stop bit setting Every character has a stop bit in the end during the data transmission which means the end of transmission of this character. To set the stop bit (one or two) based on the requirement of your host.
Reset to default configuration retard of characters(default 0ms) 2.6 Prefix and suffix setting 2.6.1 Prefix and suffix setting You can set at most one prefix and two suffix attach to the scan data. To set this prefix and suffix, you need to scan four number (means four barcode in Appendix II and II) based on ASCII. If you want to change or cancel one incorrect setting, scan the “cancel setting” in the appendix.
Reset to default configuration Barcode + suffix 2 Barcode + suffix 1 + suffix 2 Prefix + barcode Prefix + barcode+ suffix 1 Prefix + barcode+ suffix 2 Prefix + barcode+ suffix 1 + suffix 2 2.7 Mark barcode transfer type setting 2.7.1 Disable mark barcode transfer type Disable mark barcode transfer type 2.7.
Reset to default configuration 2.8 Chinese character encode 2.8.1 Disable Chinese character encode Disable Chinese character encode 2.8.2 GBK(GB2312) Be suited to TXT、Excel type software display. Default setting. GBK(GB2312) 2.8.3 UNICODE Be suited to QQ、WORD type software display.
Reset to default configuration 3、Serial port instructions The serial port version of these products can set all basic setting 、light and volume、decode function、 communication mode 、prefix and suffix and so on by serial port instructions.
Reset to default configuration (continuous scanning mode) 0.5s: 07 C6 04 08 00 89 05 FE 99 3s:07 C6 04 08 00 89 1E FE 80 Null :08 C6 04 08 00 F2 05 00 FE 2F CRLF:08 C6 04 08 00 F2 05 01 FE 2E End mark Enter:08 C6 04 08 00 F2 05 02 FE 2D TAB: 08 C6 04 08 00 F2 05 03 FE 2C Turn on/Turn off configuration code Enable\Disable sending setting code Enable :07 C6 04 08 00 EC 01 FE 3A Disable :07 C6 04 08 00 EC 00 FE 3B Enable :08 C6 04 08 00 F1 71 01 FD C3 Disable :08 C6 04 08 00 F1 71 00 FD C4 Continuous power
Reset to default configuration Off: 08 C6 04 08 00 F2 0B 00 FE 29 Decode indicator light On: 08 C6 04 08 00 F2 0B 01 FE 28 Volume-Low:07 C6 04 08 00 8C 02 FE 99 Volume setting Volume-Middle: 07 C6 04 08 00 8C 01 FE 9A Volume-High: 07 C6 04 08 00 8C 00 FE 9B On: 08 C6 04 08 00 F2 0C 01 FE 27 Mute Off: 08 C6 04 08 00 F2 0C 00 FE 28 On: 08 C6 04 08 00 F2 0D 00 FE 27 Starting up sound setting Off:08 C6 04 08 00 F2 0D 01 FE 26 On: 08 C6 04 08 00 F2 0E 00 FE 26 setting code volume Off: 08 C6 04 08 00 F2 0E 01 F
Reset to default configuration 3.3 Enable\Disable decode function Instructions(HEX ) Function off:07 C6 04 08 00 2D 00 FE FA on:07 C6 04 08 00 2D 02 FE F9 code system character output For example:C ode 93 read 012345678905 and come out result with G012345678905 G means Code93 off:07 C6 04 08 00 01 00 FF 26 UPC-A on: 07 C6 04 08 00 01 01 FF 25 off: 07 C6 04 08 00 02 00 FF 25 UPC-E on: 07 C6 04 08 00 02 01 FF 24 off:07 C6 04 08 00 25 00 FF 02 Convert UPC-E TO UPC-A on: 07 C6 04 08 00 25 01 FF 01 off: 07
Reset to default configuration off:07 C6 04 08 00 0E 00 FF 19 GS1-128 on:07 C6 04 08 00 0E 01 FF 18 off:07 C6 04 08 00 54 00 FE D3 ISBT 128 on:07 C6 04 08 00 54 01 FE D2 off:07 C6 04 08 00 00 00 FF 27 Code 39 on:07 C6 04 08 00 00 01 FF 26 off:07 C6 04 08 00 09 00 FF 1E Code 93 on:07 C6 04 08 00 09 01 FF 1D off:07 C6 04 08 00 0A 00 FF 1D Code 11 on:07 C6 04 08 00 0A 01 FF 1C off:07 C6 04 08 00 06 00 FF 21 ITF25 on:07 C6 04 08 00 06 01 FF 20 off:07 C6 04 08 00 05 00 FF 22 industrial ITF25 on:07 C6 04 08 00 05
Reset to default configuration off:08 C6 04 08 00 F1 3D 01 FD F7 MicroQRCode on:08 C6 04 08 00 F1 3D 00 FD F8 off:08 C6 04 08 00 F0 24 01 FE 11 DataMatrix on:08 C6 04 08 00 F0 24 00 FE 12 off:08 C6 04 08 00 F0 26 00 FE 10 MaxiCode on:08 C6 04 08 00 F0 26 01 FE 0F off:08 C6 04 08 00 F0 28 00 FE 0E Aztec on:08 C6 04 08 00 F0 28 01 FE 0D off:08 C6 04 08 00 F0 2F 00 FE 07 Chinese code on:08 C6 04 08 00 F0 2F 01 FE 06 3.
Reset to default configuration 1ms: 07 C6 04 08 00 6E 01 FE B8 The retard of characters 99ms: 07 C6 04 08 00 6E 63 FE B8 3.
Reset to default configuration C Code 128, ISBT 128, GS1-128 E UPC/EAN, Coupon (UPC portion) F Codabar G Code 93 H Code 11 I Interleaved 2 of 5 M MSI S Discrete 2 of 5, IATA 2 of 5 X Code 39 Trioptic, Bookland EAN, Han Xin e GS1 D ataBar L PDF417 d Data Matrix(DM) Q QR z Aztec Code U Maxi Code m modifier meaning: Code type Value 0:Standard data package, no function code 1 in the first character position. 1:Function code 1 in the first character position.
Reset to default configuration appendix Appendix 1 Number setting code When setting needs exact number, scan the barcode below to set numbers.
Reset to default configuration 9 Cancel Change setting or cancel one wrong barcode by scan this barcode.
Reset to default configuration Appendix 2 set prefix and suffix by serial port instructions Add prefix and suffix to the barcode: 1. set scanning data transport format (parameter 0Xe2) to what you need. 2. You need to change the ASCII code into hex system so that you can import these codes you want to set in the prefix 1(0x69), suffix 1(0x68) or suffix 2(0x6A).
Reset to default configuration 1033 21h ! 1034 22h ‘ 1035 23h # 1036 24h $ 1037 25h % 1038 26h & 1039 27h ‘ 1040 28h ( 1041 29h ) 1042 2Ah * 1043 2Bh + 1044 2Ch , 1045 2Dh - 1046 2Eh .
Reset to default configuration 1076 4Ch L 1077 4Dh M 1078 4Eh N 1079 4Fh O 1080 50h P 1081 51h Q 1082 52h R 1083 53h S 1084 54h T 1085 55h U 1086 56h V 1087 57h W 1088 58h X 1089 59h Y 1090 5Ah Z 1091 5Bh [ 1092 5Ch \ 1093 5Dh ] 1094 5Eh ^ 1095 5Fh _ 1096 60h ‘ 1097 61h a 1098 62h b 1099 63h c 1100 64h d 1101 65h e 1102 66h f 1103 67h g 1104 68h h 1105 69h i 1106 6Ah j 1107 6Bh k 1108 6Ch l 1109 6Dh m 1110
Reset to default configuration 1119 77h w 1120 78h x 1121 79h y 1122 7Ah z 1123 7Bh { 1124 7Ch | 1125 7Dh } 1126 7Eh ~ 1127 76h v 40
Reset to default configuration Appendix 3 : barcode sample Name Barcode sample Remark EAN13 UPC-A EAN8 UPC-E Default data: 1234565 Codabar Encoded data: c01235d Code93 Code39(Regular) Encoded data: *Code 39 Code 39(FullASCII) 41