Chapter 3 Electrical characteristics
6
operation to achieve the lowest consumption.
E4000 is less than 4s from power on to completion. After turning off the power, it is recommended to allow the power input
to be turned on again after more than 500ms.
Ripple noise
Since the power input of the E4000 is directly supplied to the image sensor and the decoder chip, a low ripple noise
power input is required to ensure stable operation. It is recommended to control the ripple noise to within 50mV (peak-to-
peak), at least not to exceed 100mV.(peak-to-peak).