User manual

8X96 ADC and DAC User Manual Page 31 of 54
for current literature, manuals and online email support check http://www.mytekdigital.com
implemented this setting after discovering that Tascam DA88 machine outputs “rubbish”
on bits 17-24.
Cloning MDM Connectors (default disabled) – This setting is active in S/MUX or
MRX mode and with ADAT and TDIF cards only. The cloning function is primarily
intended for output to a backup machine and for easy A/B’ing of two sources.
Since the cards feature 2 sets of connectors called “machine A” and “machine B” and the
ADC is 8x24/96, while connectors are 44/48k, there are several modes the unit can
operate with.
Cloning disabled, (88/96k, MRX OFF):
All channels are sample-split (S/MUX) . Channels 1-4 are output/input in
S/MUX pairs on connector A and channels 5-8 are on connector B.
Machine A/B select switch is not operational.
Cloning disabled, (88/96k, MRX MODE1–96 =4x24@88/96):
Channels 1-2 and 5-6 are bit-split (MRX) . Channels 1-2 are output/input
in MRX pairs on connector A and channels 5-6 are on connector B.
Channels 3,4,7,8 are not used.
Machine A/B select switch is not operational.
Cloning disabled, (88/96k, MRX MODE2–96 =6x20@88/96):
Channels 1-3 and 5-7 are bit-split (MRX) . Channels 1-3 are output/input
in MRX pairs on connector A and channels 5-7 are on connector B.
Channels 4,8 are not used.
Machine A/B select switch is not operational.
Cloning disabled, (44/48k, MRX MODE1 =8x24@44/48):
Channels 1-8 are bit-split (MRX) . Channels 1-4 are output/input in MRX
pairs on connector A and channels 5-8 are on connector B.
Machine A/B select switch is not operational.
Cloning enabled, (MRX OFF):
Channels 1-4 are sample-split (S/MUX) . Channels 1-4 are output/input in
S/MUX pairs on connector A and B simultaneously. Machine A/B select
switch can select the source to be either connector A or B.
Cloning enabled, (88/96k, MRX MODE1–96 =2x24@88/96):
Channels 1-2 are bit-split (MRX) . Channels 1-2 are output/input in MRX
pairs on connector A and B simultaneously. Channels 3-8 are not used.
Machine A/B select switch can select the source to be either connector A
or B.