Latency Compensantion Chart
Nr Fs [kHz] Latency
compensation
disabled
Latency compensation enabled
in+out latency in+out latency Output
Latency
Input
Latency
1. 44.1 112 30 0 30
2. 48 112 30 0 30
3. 88.2 85 41 9 32
4. 96 85 41 9 32
5. 176.4 47 7 0 7
6. 192 47 7 0 7
User's Manual ver. 2.0 / Nov 2013 www.mytekdigital.com Page: 31 / 32