Controls and Ports
TEST PLUG Allows you to test camera head
separately from push rod MyTana classic style
cams (w/pins) only
1. Unplug push-rod reel
cord from REEL port
2. Disconnect camera head from the push rod,
then carefully insert in to this port to test
REEL Connect push-rod patch cord here,
classic style (w/pins) only
COUNTER RESET Resets footage counter to zero
REEL SELECT
Selects reel size you are using to keep footage
count accurate.
MSA- = mini reel (100’)
MS11- = mid-sized reel (150’ or 200’)
MY30 (NGx10) = large reel (200’)
PGR400 = muni reel (400’)
Also, hold REEL SELECT button for 3 seconds to
switch from feet to metric (or metric to feet)
LED CONTROL
Full clockwise = full brightness
POWER SOURCE RECEPTACLE
Any 3 prong extension cord can be used to
power unit or recharge battery. Can be
plugged in to standard wall outlet.
POWER
u Give the unit 30 seconds to fully boot up
Blinking Blue light indicates low battery.
It will blink for 5-10 minutes before battery fails.
Plug unit in to standard wall outlet to recharge.
TRANSMIT
Generates 512hz signal at camera head
for locating (has nothing to do with Wi-Fi).
Will lose picture and lights on camera
NOTE: You must be in Transmit mode to
display the Footage count, or use either
the Reel Select or Counter Reset buttons.
Transmit button may also remove
persistent logo splash screen.
Microphone
IMPORTANT!
Use these CONTROL PANEL buttons
for recording and working with les.