Q: Why does the GFI trip immediately upon power up?
A: 1. If this is a new installation, make sure GFI breaker is wired correctly.
Refer to page #10 .
2. Disconnect all the components (pumps, ozonator, and plug them back in one
at a time to verify which component is causing the GFI to trip.
3. Check for any loose connections or cut wires in the box.
If problem persist contact your dealer or manufacturer.
Q: Why is my spa running all the time?
A: Check your filtration settings, you might be in continues filtration mode “Filc” or just
set in a high filtration. Factory setting is F2 or Fil 2 which means your spa will filtrate
2 hours out of every 12 hours. Twice a day. If problem persists contact your dealer or
manufacturer.
Q: After powering up my spa, Why do I get a Dr or Dry code on my topside dis-
play?
A: This indicates that there is insufficient amount of water in your heating tube, due
to an air lock in your pump. Which is an air bubble in the water lines. You will need to
bleed your pump or pumps. Refer to page 13. If problem persists contact your dealer or
manufacturer.