Operating instructions
16
System Settings (except Monaco spa)
When your spa is first actuated, it will go into Priming mode, indicated by “Pr.” The Priming
mode will last for less than 5 minutes (press “Warm” or “Cool” to skip Priming Mode) and then
the spa will begin to heat the spa and maintain the water temperature in the Standard mode.
The start-up temperature is set at 100°F/37°C. The last measured temperature is constantly
displayed on the LCD.
Note that the last measured spa temperature displayed is current only when the circulator pump
has been running for at least 2 minutes.
To display the set temperature, press the “Warm” or “Cool” pad once. To change the set tem-
perature, press the pad a second time before the LCD stops flashing. Each press of the “Warm”
or “Cool” pad will continue to either raise or lower the set temperature. After three seconds, the
LCD will stop flashing and display the current spa temperature.
Jets 1
Touch the “Jets 1” button once to turn pump 1 on or off, and to shift between low and high
speeds (if equipped). If left running, the low speed of the pump will automatically turn off after
4 hours, and the high speed will automatically turn off after 15 minutes.
Jets 2 (If equipped)
Touch the “Jets 2” button once to turn pump 2 on or off. If left running, pump 2 will automatically
turn off after 15 minutes.
To program, press WARM, then JETS. Press WARM to adjust from 2 -8. Press JETS to
exit programming. The default filter time is two (2) hours.