Mode (OPTIONAL)
All Syberian series spas (except the Monaco) are factory set in STANDARD MODE.
Mode is changed by pressing the “Warm” or “Cool” button, then pressing the “Mode” button. For
Monaco MODE is changed by pressing “Warm” or “Cool”, then pressing LIGHT button.
Standard Mode is programmed to maintain the desired temperature. Note that the last mea-
sured spa temperature displayed is current only when the pump has been running for at least 2
minutes. “Std or St” will be displayed momentarily when you switch into Standard Mode.
Economy Mode heats the spa to the set temperature only during filter cycles. “Ecn or Ec” will
display solid when temperature is not current, and will alternate with temperature when tem-
perature is current.
Sleep Mode also heats the spa to the set temperature only during filtration cycles “Slp or Sl ”
will display solid when temperature is not current, and will alternate with temperature when tem-
perature is current, but only within 20 degrees of your set temperature.
If you would like to use
Economy or Sleep Mode you must ip dip switch #7 to the OFF position.
SEE FIGURE 5 BELOW.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C within the heater, the pumps will
automatically activate to provide freeze protection. The equipment stays on until 4 minutes
after the sensors detect that the spa temperature has risen to 45°F/7.2°C or higher. In colder
climates, an optional additional freeze sensor may be added to protect against freeze conditions
that may not be sensed by the standard sensors. Auz freeze sensor protection acts similarly
except with the temperature thresholds determined by the switch and with out a 4-minute delay
in turnoff. See your dealer for details.
(Figure 5)
FOR MONACO ONLY.
ALL OTHER ACRYLIC SPAS THE MODE FEATURE IS FACTORY SET.