Operating instructions

QUESTIONS? PROBLEMS? PLEASE CALL YOUR DEALER FOR HELP.
12
ON ON ON ON ON
OFF OFF OFF OFF OFF
House Breaker Box
Neutral Hot
Ground
USE COPPER 230V
WIRE MIN. 8 AWG - 20A 50Hz
SPA CIRCUIT BOARD
N
N
1
2
0 OFF
TEST
BROWN (HOT)
BROWN (HOT)
BROWN (HOT)
BLUE (NEUTRAL)
BLUE (NEUTRAL)
BLUE
(NEUTRAL)
GREEN/
YELLOW
(GROUND)
GREEN/
YELLOW
(GROUND)
GREEN/
YELLOW
(GROUND)
L1
L2
GRND
Two Wire & Earth
(Also known as Ground)
These wires go to
the PC Board Control
Circuit.
Earth/Ground = Green & Yellow wire
L1 = Positive/Live = Brown wire
L2 = Negative/Neutral = Blue wire
230 Volt - Single service 1x16 - 20 AMP Breaker
230 Volt - Double service 1x32 - 40 AMP Breaker
Electrical Connections
Substitute these common HOT, NEUTRAL, EARTH GROUND colors for your countries standard.
PLEASE CHECK YOUR LOCAL BUILDING CODES AND ONLY USE A CERTIFIED ELECTRICIAN TO
INSTALL ANY ELECTRICAL COMPONANTS TO YOUR SPA.
EUROPEAN WIRING DIAGRAM
ILLUSTRATIONS COURTESY OF BALBOA INSTRUMENTS
THIS SECTION IS FOR EUROPEAN USERS ONLY