STRONG SPAS OWNERS MANUAL United States & European Models Syberian Series Barcelona, Madrid, Vienna, Monaco, Seville, & El Dorado IT SUBM HIN 30 O T E R IT FAILU N CARD W S ALL O I ID TRAT SE VO S I A G H E C R R OF PU RANTIES DAYS WAR PLEASE READ THIS MANUAL BEFORE ATTEMPTING TO OPERATE YOUR NEW SPA CAUTION: Having more than one GFCI used on the electrical circuit will render the spa inoperable. The spa must be on a dedicated circuit. 1-800-STRONG-9 P.O.
TABLE OF CONTENTS Introduction / Knowing Your Spa............................................. 3 Safety Instructions....................................................................... 4 Installation Instructions.............................................................. 5 Filling Your Spa............................................................................. 6 Spa Maintenance.......................................................................... 7 Winterizing Your Spa...................
INTRODUCTION Congratulations on your purchase of our Syberian Series spa. We at Strong Pools & Spas are excited to assist your family in “Creating a Lifestyle that Lasts a Lifetime”. With proper care, operation and maintenance, your spa will provide your family many years of comfort and pleasure. Please take time to read all the instructions before you install or operate your Strong Spa. This manual explains safety precautions, installation instructions, operating directions and maintenance procedures.
IMPORTANT SAFETY INSTRUCTIONS WARNING: People with infectious diseases should not use a spa. The use of alcohol, drugs or medication before or during spa use may lead to unconsciousness with the possibility of drowning. DO NOT use the spa immediately following strenuous exercise. Persons suffering from heart disease, diabetes, high or low blood pressure or any other serious illness and pregnant women should consult with their physician before using the spa. Excessive water temperature can be dangerous.
INSTALLATION INSTRUCTIONS Spa Location: Improper installation may result in equipment damage and will void the warranty. Your spa must be placed on a flat, level surface. The space you choose to install your spa is a very important decision, you should consider all of the listed suggestions. Check your local code office for understanding of building, fencing, gates, electrical, plumbing and enclosure required codes.
FILLING YOUR SPA WITH WATER THROUGH THE FILTER Make sure all gate valves are in the UP position (and white plastic clips are inserted), also make sure heater unions are tight. Be sure to check that blue ball valve on drain is turned to the off position (counter-clockwise). Make sure the black cap on the drain is tightened. Be sure pump suction and pressure unions are tight.
Filling You Spa Through the Filter Place the hose into the filter chamber (as shown), this will ensure the water goes through the filter and removes the air bubbles out of the lines while you fill the system. Filling You Spa Through the Filter (Monaco Only) Place the hose into the filter chamber (as shown), this will ensure the water goes through the filter and removes the air bubbles out of the lines while you fill the system.
Since the water capacity of your spa is far less than that of a swimming pool, the chemical reaction caused by the presence of one or more persons in the spa is more rapid and pronounced. In other words, it is much more difficult to maintain the proper pH balance in a spa than in a swimming pool. For these reasons, it is important to check frequently, the total alkalinity of the water, the pH level, and the sanitize level, then add prescribed chemicals as necessary to maintain the proper chemical balance.
(FIGURE 2) (FIGURE 1) (FIGURE 3) (FIGURE 4) Note: Damage caused by improper winterizing will not be covered under warranty. You may want to contact a professional for proper winterizing. If you have any questions, please call your dealer or tech support.
Syberian Spa 220 Volt Wiring Diagram House Breaker Box OFF OFF OFF OFF OFF RECOMMENDED ON ON ON ON ON 50 AMP GFI Rated Breaker 6 Guage, 4 wire RED (HOT) BLACK (HOT) GRN WHT ON BOTTOM VIEW OF G.F.C.I. (SQUARE D) OFF G.F.C.I. Breaker Box Front View of G.F.C.I.
Your wiring should look like this. If wiring appears differently, DO NOT power your spa and contact our tech support for assistance. 220V THREE WIRE & GROUND N L1 L2 GRND THESE WIRES GO TO THE PC BOARD CONTROL CIRCUIT QUESTIONS? PROBLEMS? PLEASE CALL YOUR DEALER FOR HELP.
THIS SECTION IS FOR EUROPEAN USERS ONLY EUROPEAN WIRING DIAGRAM House Breaker Box ON ON ON ON ON OFF OFF OFF OFF OFF BROWN (HOT) BLUE (NEUTRAL) GREEN/ YELLOW (GROUND) BROWN (HOT) BLUE (NEUTRAL) N 1 TEST 0 OFF #-6 #3/ (3/ Ground GREEN/ YELLOW (GROUND) Hot USE COPPER 230V WIRE MIN. 8 AWG - 20A 50Hz GREEN/ YELLOW (GROUND) Neutral N BLUE (NEUTRAL) BROWN (HOT) 4:45&.
Prior to spa operation, plumbing fittings on pump & control pack must be tightened. Spa is shipped with loose unions to avoid damage during transportation. There are FOUR unions that require hand tightening prior to operation of your spa. When filling the spa with water, keep observing these fittings for any slight water drips. If a drip is observed, just hand tighten until dripping ceases. REMOVING AN AIR LOCK NOTE: See Union Adjustment Information before operating spa.
Mode (OPTIONAL) All Syberian series spas (except the Monaco) are factory set in STANDARD MODE. Mode is changed by pressing the “Warm” or “Cool” button, then pressing the “Mode” button. For Monaco MODE is changed by pressing “Warm” or “Cool”, then pressing LIGHT button. Standard Mode is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes.
System Settings (except Monaco spa) When your spa is first actuated, it will go into Priming mode, indicated by “Pr.” The Priming mode will last for less than 5 minutes (press “Warm” or “Cool” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode. The start-up temperature is set at 100°F/37°C. The last measured temperature is constantly displayed on the LCD.
Light Press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 4 hours unless manually turned off prior to 4 hours Mode Mode is changed by pressing the “Warm” or “Cool” button, then pressing the “Mode” button. Standard Mode is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the circ pump has been running for at least 2 minutes.
SYSTEM SETTINGS (Monaco Only) When your spa is first actuated, it will go into Priming mode, indicated by “Pr.” The Priming mode will last for less than 5 minutes (press “Warm” or “Cool” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode. The start-up temperature is set at 100°F/37°C. The last measured temperature is constantly displayed on the LCD.
Preset Filter Cycles The first filter cycle begins 6 minutes after the spa is energized. The second filter cycle begins 12 hours later. Filter duration is programmable for 2, 4, 6, 8 hours or for continuous filtration (indicated by “Filc”). The default filter time is 2 hours. To program, press “Warm” or “Cool”, then “Jets”. Press “Warm” or “Cool” to adjust. Press “Jets” to exit programming.
Diagnostic Messages (Not for Monaco) No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Spa settings will be preserved until next power up. Problem: Temperature unknown. Solution: After the pump has been running for 2 minutes, the temperature will be displayed. Problem: “Overheat”- The spa has shut down. One of the sensors has detected 118 F/43 C at the heater. Solution: DO NOT ENTER THE WATER.
Problem: Sensors are out of balance. If alternating with spa temperature, it may just be a temporary condition. If flashing by itself, spa is shut down. Solution: If the problem persists, contact your dealer or service organization. Problem: A significant difference between temperature sensors has been detected. This could indicate a flow problem. Solution: Check water level in spa. Refill if necessary.
Diagnostic Messages (Monaco Only) Problem: No message on display. Power has been cut off to spa. Solution: The control panel will be disabled until power returns. Spa settings will be preserved until next power up. Problem: Temperature unknown. Solution: After the pump has been running for 2 minutes, the temperature will be displayed. Problem: “Overheat” - The spa has shut down. One of the sensors has detected that 110ºF/43ºC at the heater. Solution: DO NOT ENTER THE WATER.
Problem: A significant difference between temperature sensors has been detected. This could indicate a flow problem. Solution: Check water level in spa. Refill if necessary. If water level is okay, make sure the pumps have been primed. If problem persists, contact your dealer or service organization. Problem: Persistent low flow problems. (Displays on the fifth occurrence of “HFL” message within 24 hours.) Heater is shut down, but other spa functions continue to run normally.
Removing and Replacing the Filter on your Barcelona, Madrid, and Vienna spa. FIGURE 1 FIGURE 2 To remove the filter in your spa you must first reach into the filter chamber, then turn the weir counterclockwise until you hear the cover unlock (FIGURE 1). Lift out the weir (FIGURE 2) and remove the filter basket (FIGURE 3). Then lift out the filter (FIGURE 4). Reverse the order to replace with a new filter. FIGURE 3 FIGURE 4 Removing and Replacing the Filter on the Monaco, El Dorado, and Seville Spa.
Jets & Drain Strong Spas come with the following types of jets, cluster, directional, and spinner. They range in sizes form 2” to 5”, are adjustable and come only in Stainless Steel. (Jet sizes subject to change) The suction drain is used for filtration, circulation, and draining your spa. It is located in the foot well at the bottom of your spa. Be sure that the filter plug is removed with the filter when removing the filter.
HARD COVER The Hard Cover & cabinet is designed to last years with minimal cleaning and maintenance. Cleaning should be done regularly using only mild detergent and water, generally using a garden hose is sufficient. DO NOT USE ANY BLEACHES, HARSH CHEMICALS, SCOURING PADS, BRILLO PADS OR SAND PAPER TO CLEAN YOUR SPA! Damages caused by using any of the above will not be covered under warranty. S Y BERIA N S PA S 26 QUESTIONS? PROBLEMS? PLEASE CALL YOUR DEALER FOR HELP.
OPENING AND CLOSING THE HARD COVER Grab the handle with two hands, lift the hard cover directly upward. Slide the hard cover toward your body, the cover should easily slide and there should be minimal resistance. Lower the cover to the ground, the cover will rest on the resin brackets .on the underside of the cover. To close the cover, reverse the steps until both sides of the cover are in place and lock.
OPTIONAL STEREO SYSTEM Tsunami Waterproof | AM/FM | Weatherband | CD/CD-R /CD-RW/MP3 | Full iPod Controls | SIRIUS Satellite Radio Ready | Auxiliary Input | 200 Watts | Full Dot Matrix Display Waterproof (IPX5 rated) | ASTM B117 Salt Spray Exposure Compliant | Sealed Chassis | 40 Seconds of Skip Protection Tsunami Sound System only available in the Vienna and Madrid spas.
Remote Control Remote control allows you to control the stereo from your spa. Remote control only available for Tsunami Sound System. 2" Pop-Up Speakers New Pop up Design Round Hole Pattern for Easy Assembly Three-Way Speaker Delivers Low, Medium, and High Pitch Sounds.
STEP AND TOWEL WARMER The step and towel warmer is built into the spas cabinet system, all Syberian series spas except the Monaco come with a step and towel warmer. The towel warmer is heated by the excess heat from your pumps. On all European models, the lighted step and towel warmer is only available if you purchase a stereo package with your spa. On all American models the lighted step and towel warmer is available without the stereo options.
TROUBLESHOOTING No power to spa: 1. Check proper connection to the pack 2. Check fuse in pack. (30 AMP Slow Blow) 3. Must have very good ground connection - If none call your dealer. Trips Breaker: 1. Make sure your spa is on a dedicated line. 2. Check breaker to make sure it is wired properly. 3. First take note to how the pump runs before it trips. Trips instantly: 1. Mis-wired - check electrical wiring. 2. Breaker replacement. 3. Short in Ozone - unhook to check - call your dealer. 4.
FREQUENTLY ASKED QUESTIONS Q: Why is my spa not heating? A: You might be in “ECONOMY” or “SLEEP” mode, refer to page 15 for mode options. The spa MUST be in STANDARD mode for continuous heating. If problem persists, please contact your dealer or manufacturer. Q: Why does the system power input fuse (30 A) keep blowing? A: Chances are the control box is improperly wired or is connected to an insufficient power source. Check all wires to GFI Breaker, and check all wires from GFI to your control box.
Q: Why does the GFI trip immediately upon power up? A: 1. If this is a new installation, make sure GFI breaker is wired correctly. Refer to page #10 . 2. Disconnect all the components (pumps, ozonator, and plug them back in one at a time to verify which component is causing the GFI to trip. 3. Check for any loose connections or cut wires in the box. If problem persist contact your dealer or manufacturer.
WARRANTY Spa Surface (Acrylic): 7 years Strong Spas warrants the original retail purchaser the surface integrity of the spa against blistering or delaminating as a result of defects in material or workmanship for a period of 7 years. (repair or replacement) Plumbing & Equipment: 5 years Strong Spas warrants the original retail purchaser the integrity of the spas plumbing against leaks as a result of defects in material or workmanship for a period of 5 years. (parts and labor).
LIMITATIONS THIS LIMITED WARRANTY IS NONTRANSFERABLE AND ONLY APPLIES TO THE ORIGINAL PURCHASER. THIS LIMITED WARRANTY SUPERSEDES THE PLACE OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, IN FACT OR AT LAW, INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. ALL WARRANTY SERVICE MUST BE AUTHORIZED BY STRONG SPAS AND PERFORMED BY ITS AUTHORIZED AGENT.
RETAIN THIS BOOKLET FOR FUTURE REFERENCE A PDF VERSION OF THIS MANUAL IS ALSO AVAILABLE BY CALLING TECH SUPPORT FOR ANY MISSING PARTS, PROBLEMS, OR QUESTIONS CALL: MONDAY _ FRIDAY 9:00AM to 5:00PM EST. (570) 275-2700 Be sure to have your spas serial number, model, and date of purchase ready when calling. PLACE STAMP HERE POOLS & SPAS 3204 Point Township Drive (Route 11) P.O. BOX 108 Northumberland, Pa 17857 U.S.A.