Operating instructions

23
Myson Touch RS
N
L
N
E
MYSON
(Heating)
MPE222
Brown.
Grey.
Blue.
Orange.
E
N
L
E N N
S/L
P/L
P&B
S/L
H = HEATING
P&B = PUMP & BOILER
E = EARTH
N = NEUTRAL
P/L = PERMANENT LIVE
S/L = SWITCHED LIVE
REMOTE SENSOR
Installation or repair only by qualified personnel & in accordance with IEE regulations.
Note 1: A Class 'A' switch, (contact separation of at least 3mm in all poles) must be
To protect the system a fuse rated at 3 amps must be installed.
Disconnect mains supply before doing any maintenance or installation work.
Note 2: See boiler & pump instructions to determine their precise wiring requirements,
incorporated in the fixed wiring as a means of disconnecting the supply voltage.
with particular reference to pump "over-run"
MYSON TOUCH RS
(note 2)
Boiler
Pump.
(note 2)
Power Input.
230V ac
(note 1)
E
L
N
50Hz.
Typical Wiring
RT
A
N
MYSON TOUCH RS
+
C
O
HEATING
L
1
A
2-
H