Specifications
T6 Radiator Series
MYSON
Optional Piping Arrangements
The following drawings are general
examples. They are diagrammatic only.
Consult a certified heating professional
for your specific application.
General information on the use of Monoflo tees:
• Scoop type is placed on the supply
• Venturi type on the return
• If heating unit is below main or more than 4
feet horizontally from the main, use two
monoflo tees facing each other
TheT6radiator is designedtobeconnected
usingthe2”ccbottomcenterconnections.
Theseconnectionsutilizetheefficientuseof
specialinternalpipingandtheincluded
internalThermostaticRadiatorValve.The
“HomeRunSystem”pipingwithamodulating
circulatoristhemostefficientinstallation
method.Thebottomcenterconnectionsalso
workwe
llwiththe“Monoflo(1Pipe)Syste
m”.
Ifconnectedinseries(“SeriesLoop”)an“H”
styleby‐passvalvemustbeusedandthecircuit
mustbelimitedto2gpm.Thismethodisnot
recommended.
TheT6radiatormayalsobeinstalledusingthe
alternateendpaneltappings,howeverthi
swill
rendertheinternalpipingandTRV
non‐
o
p
erationalandisnotrecommended.
8