23672 Slimline RC Manual 27/06/2011 09:30 Page 2 Installation, Operating, Maintenance and After Sales Manual. SLIM-LINE RC heatingthroughinnovation. 01.06.2011 ISSUE 4 Product Serial Number: Please leave this manual with the end user.
3672 Slimline RC Manual 27/06/2011 09:30 Page 3 Contents 1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 Water Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedure 07 10.0 Technical Data 08 11.0 Operating Instructions 09 12.0 Troubleshooting 10 13.
23672 Slimline RC Manual 27/06/2011 09:30 Page 4 SLIM-LINE RC 03 Fan only with water temperature control – allows the user to select any of the available fan speeds, which will operate only if the water temperature in the coil is above 32C. This enables control of the unit via an externally mounted room thermostat if desired. l The SLIM-LINE RC can be used on heat pump systems. l The minimum side clearance is 100mm. l The maximum ceiling height is 3m.
23672 Slimline RC Manual 27/06/2011 09:30 Page 5 04 SLIM-LINE RC 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. SLIM-LINE RC unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Fixing kit (rubber mounts and cable gland). 6. Remote control handset. 6.0 Fixing l Using the fixing dimensions (see fig. 1), mark the fixing hole positions on the wall. l Drill and plug the wall for No.
23672 Slimline RC Manual 27/06/2011 09:30 Page 6 SLIM-LINE RC 05 7.0 Water Connections l Connect unit to system flow and return pipes using the two 15mm isolating valves (see fig. 2). l Ensure system is flushed in accordance with recognised best practice and a suitable inhibitor is added to the system as necessary. Note: To ensure effective venting of the heat exchanger the flow pipe should be connected to the bottom connection of the heat exchanger.
23672 Slimline RC Manual 27/06/2011 09:30 Page 7 06 SLIM-LINE RC 8.0 Electrical Connection WARNING: This appliance must be earthed. The electrical installation must comply with local or national wiring regulations. l This unit is supplied with factory fitted test leads. Remove these and discard. l Connect live and neutral wires to the power board terminal connections, and the earth wire to the chassis earth terminal.
23672 Slimline RC Manual 27/06/2011 09:30 Page 8 SLIM-LINE RC 07 9.0 Commissioning Procedure l Fill and vent the system. l Isolate electrical supply. l Open both valves fully and vent air from the heat exchanger by unscrewing the air bleed valve situated above the valves in the angled top of the chassis. l Remove outer cover. l Check for leaks at pipe connections. l Refit the outer case and secure using the 2 fixing screws. l Switch on electrical supply.
23672 Slimline RC Manual 27/06/2011 09:30 Page 9 08 SLIM-LINE RC 10.
23672 Slimline RC Manual 27/06/2011 09:30 Page 10 SLIM-LINE RC 09 11.0 Operating Instructions Description This SLIM-LINE RC unit is fitted with a control system that provides 3 different operating modes. In automatic mode the desired temperature set point is selected and the unit will adjust the fan speed according to the difference between the actual room temperature and the set point.
23672 Slimline RC Manual 27/06/2011 09:30 Page 11 10 SLIM-LINE RC 11.0 Operating Instructions (continued...) Operation Display Manual Power off No Display Manual mode can be used for air circulation without heat or for manual control of the heating function.
23672 Slimline RC Manual 27/06/2011 09:30 Page 12 SLIM-LINE RC 12.0 Troubleshooting 11 (continued...
23672 Slimline RC Manual 27/06/2011 09:30 Page 1 MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk Serial Number Location: Inner chassis position heatingthroughinnovation. After Sales Service: Spare parts and technical help on all Convector products are available from MYSON Service. 01.06.2011 ISSUE 4 MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.