Technical data
04
KICKSPACE
®
500, 600, 600-12V & 800
5.0 Preparation (continued...)
l A clean and level floor area is required under the cupboard
base.
l Floor mounting - The KICKSPACE
®
is normally fitted directly
onto the floor and the base of the unit is fitted with four
mounting feet.
l Plinth mounting -
• As an alternative to floor mounting the unit may be
fitted into the plinth.
• A suitable support must be securely fitted to the floor.
• The top of the support must be level with the lower
edge of the cut-out when fitted.
l Decide the position of the KICKSPACE
®
, mark out and cut the
plinth to the dimensions of Fig. 1a (floor mounting) or 1b
(plinth mounting).
Model A B
Dimensions (mm)
500 466 99
600 & 600-12V 520 99
800 575 99
A
B
A = Width of cutout
B = Height of cutout
Note: unit dimensions given in Technical Data section 9.
Fig. 1a Plinth opening - floor mounting Fig. 1b Plinth opening - plinth mounting
A
B
6.0 Electrical Connection
l The electrical installation must comply with local or national
wiring regulations.
l This unit is supplied fitted with a 2 metre 0.75mm
2
cord.
l For KICKSPACE
®
500, 600 and 800, a fused (3A) electrical
spur with a switch having 3mm separation on all poles must
be provided in an easily accessible position adjacent to the
unit.
l For the KICKSPACE
®
600-12V, a fused electrical spur having
3mm separation on all poles must be provided in an easily
accessible position adjacent to the transformer. Both the
fused spur and the transformer must not be positioned in a
bathroom or other similar high humidity installation.
l Room Thermostat - If a remote room thermostat is required,
wire it into the fused spur at this stage (not KICKSPACE
®
600
12V).
l Remote Control Switch - A remote control switch is available
as an accessory, and if required should be wired at this stage.
l If the supply cord to KICKSPACE
®
models 500, 600 or 800 is
damaged, it must be replaced by the manufacturer, its
service agent or similar qualified persons in order to avoid a
hazard.
l If the supply or outlet cord to KICKSPACE
®
600-12V
transformer is damaged, it must be replaced by the
manufacturer, its service agent or similar qualified persons in
order to avoid a hazard.
l For the KICKSPACE
®
600-12V, a connector block is supplied
to connect the low voltage supply from the transformer to the
supply cord fitted to the unit.
WARNING: KICKSPACE
®
500, 600 and 800 models must be earthed.
Do not energize the electrical supply until the remaining stages of the installation have been completed.
23928 Kickspace Manual_Layout 1 27/06/2011 10:16 Page 5