Operating instructions

7
Maximum heat output (Watts)
Temperature difference (°C)
Maximum heat output (Btu/h)
Temperature difference (°F)
40°
923
733
1275
880
45°
1045
815
1453
1053
50°
1166
896
1630
1225
55°
1289
976
1803
1393
60°
1412
1056
1975
1560
65°
1535
1135
2150
1730
72°
3152
2501
4350
3002
81°
3565
2781
4959
3594
90°
3981
3058
5561
4179
99°
4398
3332
6154
4754
108°
4817
3603
6738
5322
117°
5238
3873
7336
5904
Water
content
(litres)
Model Motor
power
(Watts)
25
12
40
29
500
600 &
600-12V
0.15
0.30
Fan
speed
Boost
Low
Boost
Low
Flow rate correction factors:
453 l/h (100 g/h) multiply output by 1.03, 227 l/h (50 g/h) multiply output by 0.96, 113 l/h (25 g/h) multiply output by 0.85
Heat outputs with flow rate 75 g/h. Tested in accordance with BS 4856 Pt 1.
Noise level tests in accordance with EN 23741
ft wg mm wg
500
0.58
0.22
0.05
600 & 600-12V
1.95
1.06
0.48
75
50
25
gallons/h
500
177
68
14
600 & 600-12V
594
323
146
340
227
113
litres/h
Sound pressure at 2.5 m (dBA)
Boost
38.1
39.0
Low
25.7
29.4
Model
500
600 &
600-12V
Test pressure: 20 bar, Maximum working pressure: 10 bar
Water connections: 15 mm compression
Electrical supply: 220 - 240 V ~ 50 Hz
Approximate hydraulic resistance through fan convector
10. TECHNICAL DATA
Colour code: br-Brown, bl-Blue, bk-Black, r-Red, y-Yellow, g/y-Green/Yellow
11. WIRING DIAGRAMS
Kickspace 500 and 600 - standard wiring diagram
Kickspace 600-12V - standard wiring diagram