Operating instructions

3
3. PREPARATION
2. ELECTRICAL SUPPLY
3.1 A clean and level floor area is required under the cupboard or bath base.
3.2 Floor mounting - The Kickspace is normally fitted directly onto the floor. Four mounting feet are fitted to the
base of the unit.
Decide the position of the Kickspace, mark out and cut the plinth to the dimensions as shown in Fig. 3.2.
3.3 Plinth mounting - As an alternative to floor mounting the unit may be fitted into the plinth. For this
application cut the plinth to the dimensions as shown in Fig. 3.3.
3.4 A suitable support must be securely fitted to the floor. The top of the support must be level with the lower
edge of the cut-out when fitted.
A minimum of 25 mm clear headroom is required above the top of the Kickspace when fitted.
3.5 Flexible connection hoses with integral isolating valves are supplied to allow for easy installation and future
access for maintenance etc.
WARNING: THIS APPLIANCE MUST BE EARTHED.
The electrical installation must comply with local or national Regulations.
2.1 The Kickspace is supplied fitted with a 2 metre 0.75 mm² cord.
2.2 A fused (2A) electrical spur with a switch having 3 mm separation on all poles must be provided in an easily
accessible position adjacent to the Kickspace, as shown in Fig. 2.2.
2.3 Room Thermostat - If a room thermostat is to be fitted, wire it at this stage. Remove the link in terminals T1
and T2. Connect sufficient cord to these terminals and connect to the thermostat.
2.4 Remote Control Switch - A Remote Control Switch is available as an accessory, and if required should be
wired at this stage. Follow the instructions supplied with the kit.
Do not energize the electrical supply until the remaining stages of the installation have been completed.
Note: If the supply cord to the transformer is damaged, it must be replaced by a special cord/transformer assembly available
from Myson Convectors.
PREPARATION - continued
Fig. 3.2 - Plinth opening (floor mounting) Fig. 3.3 - Plinth opening (plinth mounting)
B
A
Base of cupboard
Kickspace 600, 600-12V
Kickspace 500
A
520
466
B
99
99
Kickspace 600, 600-12V
Kickspace 500
A
520
466
B
99
99
Fig. 2.2 - Electrical supply
ELECTRICAL SUPPLY - continued
Kickspace 500 and 600 Kickspace 600-12V