Technical data

04
KICKSPACE
®
500, 600, 600-12V & 800
A
B
Fig. 1a Plinth opening - floor mounting
Fig. 1b Plinth opening - plinth mounting
A
B
5.0 Location
l This KICKSPACE
®
unit is designed for installation in the
cavity beneath cupboards in kitchens or other similar
locations on the vacant floor space.
l When installed in a kitchen consideration should be given to
storage of perishable goods in the cupboard above.
l A minimum of 25mm clear headroom is required above the
top of the KICKSPACE
®
when fitted.
l The unit should be mounted on a clean and level floor area
under the cupboard base.
6.0 Preparation
Before proceeding with the installation, unpack the carton
contents and check against the checklist below:
1. KICKSPACE
®
unit.
2. Flexible hoses including isolating valves (1 pair).
3. Instruction manual.
4. Warranty card.
5. Grille.
6. Screw fixing kit (with grille).
7. Transformer (12V model only).
8. Connector (12V model only).
l A clean and level floor area is required under the cupboard
base.
l Floor mounting (see Fig. 1a) - The KICKSPACE
®
is normally
fitted directly onto the floor and the base of the unit is fitted
with four mounting feet.
l Plinth mounting (see Fig. 1b) -
As an alternative to floor mounting the unit may be fitted
into the plinth.
A suitable support must be securely fitted to the floor.
• The top of the support must be level with the lower edge of
the cut-out when fitted.
l Decide the position of the KICKSPACE
®
, mark out and cut the
plinth to the dimensions of Fig. 1a (floor mounting) or 1b
(plinth mounting).
Model A B
Dimensions (mm)
500 466 93
600 & 600-12V 520 93
800 573 93
A = Width of cutout
B = Height of cutout
Note: unit dimensions given in Technical Data section 10.