opened to increase the flow rate through the boiler until the noise stops.
NOTE: When the boiler is first fired, a smell may occur. This will clear within a few hours of operation.
NOTE: A limit thermostat is fitted to the boiler, wired to interrupt the thermocouple circuit, and so
causing safety shut down in the event of an overheat condition. This limit thermostat is of a self-
resetting type. Should the thermostat trip during commissioning, allow the system to cool, then relight
the boiler.
Refit the casing and control cover. Hand all instructions to the user or purchaser for retention.
Demonstrate and explain the safe and efficient operation of the boiler. Advise the user or purchaser
that for continued efficient and safe operation of the boiler, it is important that servicing is carried out
annually.