Troubleshooting guide

If your Myrinet-2000 M3-E* switch is equipped with a monitoring line card
(located in the top-slot of the switch), this monitoring line card contains 10base-T
dual ethernet ports and DHCP is required for its installation.
A Myrinet-2000 switch does not require any configuration.
Switch line cards (M3-SW16-8E, M3-SW16-8F, M3-SPINE-8F, M3-BLANK) are
hot-swappable.
A line card, a fan tray, or an enclosure is a Field Replaceable Unit (FRU). The
power supply is not an FRU; it is built into the enclosure.
We recommend the use of dust plugs in unused ports on the switch, and require
blank panels in unused slots (for cooling and EMI reasons).
You must provide proper ventilation for the switch(es), otherwise shutdown due to
overheating could occur.
After reading the documentation on the Myrinet-2000 Switches for Large Clusters, you
should be aware of the following important information and precautions pertaining to
M3-CLOS-ENCL-* and M3-SPINE-ENCL-* switches:
Each M3-CLOS-ENCL-* and M3-SPINE-ENC-*L switch is equipped with a
monitoring line card (located in the left-most-slot of the switch), and this
monitoring line card contains 10/100base-T dual ethernet ports. Assigning a static
IP address or DHCP is required for its installation.
A Myrinet-2000 M3-CLOS-ENCL-* or M3-SPINE-ENCL-* switch does not require
any configuration.
For the M3-SPINE-ENCL-* enclosure, the M3-THRU-16Q switch line cards must
be inserted in odd-numbered slots of the enclosure, and the M3-4SW32-16Q switch
line cards must be inserted in the even-numbered slots of the enclosure.
For the M3-CLOS-ENCL-* enclosure, if there are M3-THRU-16Q and M3-4SW32-
16Q switch line cards in the middle slots (slots 8-11), the M3-THRU-16Q switch
line cards must be in slots 8 and 9, and the M3-4SW32-16Q switch line cards in
slots 10 and 11.
Switch line cards (M3-SW32-16F, M3-2SW32, M3-4SW32-16Q, M3-THRU-16Q,
M3-AIRDAM) are hot-swappable.
The M3-CLOS-ENCL (or M3-SPINE-ENCL) enclosure contains four 350W power
supplies that can be individually hot-swapped, and operate in an auto-parallel
mode in which any three power supplies are sufficient to supply the maximum
power a unit may require.
© 2007 Myricom, Inc. DRAFT