Operating Instructions

SENSE MCE IBC Operating Instruction
Page 38 of 46 Release Rev. D, 2020-12-15
© MYNXG Product GmbH, 2020. All rights reserved
5.5.1 ISM Sub-1GHz Band (Frequencies North America)
The frequencies used for Sense MCE IBC for ISM communication are shown in Table 10:
Table 10: RF channels for North America
Channel
Number
Frequency
(MHz)
Average EIRP
Power (dBm)
10
PSD in any 3KHz
band (dBm)
Occupied
Bandwidth (kHz)
1
913.0
16
7.02
514.4231
2
914.0
16
7.27
514.4231
3
915.0
15
7.62
514.4231
4
916.0
15
7.68
514.4231
5
917.0
15
7.76
514.4231
Software or system compliance: Sense MCE IBC is utilizing the following network assignment
technologies in line with the above directive:
Polite Spectrum Entrance using collision detector
Sense MCE IBC always transmit below the duty cycle due to limited usage to safe
power for the sensor.
5.6 Ultrasonic Fill level measurement
The fill level is measured using the piezo sensor for ultrasonic sensing measurements. More
information regarding the fill level measurements, are shown in Table 9:
Table 11: Fill level measurement parameters
Parameter
Min
Typ.
Max
Unit
Transmit frequency
1
MHz
Number of TX pulses
0
-
31
-
Power Amplifier Gain
0
-
21
dB
Power Amplifier step size
3
dB
Low Noise Amplifier Gain
20
dB
Received signal level
35
-
1500
mV
10
The EIRP Power includes the Tx power of the transceiver and the maximum antenna gain (0 dBi)