Operating Instructions
SENSE MCE IBC Operating Instruction
Rev. D, 2020-12-15 Release Page 31 of 46
© MYNXG Product GmbH, 2020. All rights reserved
5 Electrical Standards and Specifications
IMPORTAN T NOTICE
Absolute Maximum Ratings are those values within damages on the
device will not occur. Any operation outside these maximum ratings may
cause damages on the device. Recommended Operating Conditions are
conditions under which operations of the device are intended to be
functional. Typically, values correspond to temperature TJ = 25
°
C. Unless
otherwise stated, the following conditions apply for supply voltage: Vin =
5 VDC through Wireless Charger.
5.1 Recommended Operating Conditions
The recommended operating conditions specify the values under which the device
operationally meets the specifications (Table 1). The battery can provide continuously 3A or
10A for less than 2ms in temperatures below 45
°
C.
CAUTION
Battery discharge in ambient temperatures lower than 0°C will result in
limited performance in current output and usable capacity.
Table 1: Recommended operating conditions.
Symbol
Parameter
Min.
Typ.
Max.
Unit
Vbat
Battery Voltage on the battery connector
3.0
3.7
4.2
V
Ibat
Battery maximum continuous discharge current
0.44
3
5
A
Ibatpk
Battery maximum peak discharge current
10
6
Vchg
Wireless Charger Voltage
4.5
4.9
5.0
V
Imax
Wireless Charger maximum current
1.20
A
T
discharge
The continuous discharging temperature
(limited by the connector in maximum value)
-20
-
55
°
C
T
charge
The continuous charging temperature (limited by
the connector in maximum value)
0
-
35
°
C
5
-20°C < T < 55°C (limited by connector).
6
0°C < T < 35°C for time period < 2ms