Operating Instruction
EDGE FCR 3 Operating Instruction
Rev. C, 2019-09-10 Release Page 51 of 64
© MYNXG Product GmbH, 2019. All rights reserved
The frequencies used for EDGE FCR 3 at the integrated “Extension Card” and the inserted
“Extension Card” module for the Europe ISM Band variant are shown in Table 12:
Table 12: RF channels for Europe
Channel
Number
Frequency (MHz)
Tx Power (dBm)
Duty Cycle (%) or
methods applied
Occupied
Bandwidth (kHz)
1
865.000
14
0.1 or LBT / AFA
100
2
865.400
14
1.0 or LBT / AFA
100
3
866.000
14
1.0 or LBT / AFA
100
4
866.600
14
1.0 or LBT / AFA
100
5
867.200
14
1.0 or LBT / AFA
100
6
867.900
14
1.0 or LBT / AFA
100
7
868.300
14
1.0 or LBT / AFA
100
8
868.950
14
0.1 or LBT / AFA
100
9
869.900
14
1.0 or LBT / AFA
100
10
869.525
19
<10.0 or LBT / AFA
100
11
863.400
14
0.1 or LBT / AFA
100
12
863.800
14
0.1 or LBT / AFA
100
13
864.200
14
0.1 or LBT / AFA
100
14
864.600
14
0.1 or LBT / AFA
100
6.6.2 ISM Sub-1GHz Band (Extension Card Frequencies North America)
The frequencies used for EDGE FCR 3 at the integrated “Extension Card” and the inserted
“Extension Card” module for the North America ISM Band variant are shown in Table 13:
Table 13: RF channels for North America
Channel
Number
Frequency (MHz)
Tx Power (dBm)
Duty Cycle (%)
Occupied
Bandwidth (kHz)
1
913.000
19
36
526.8
2
914.000
19
36
526.8
3
915.000
19
36
526.8
4
916.000
19
36
526.8
5
917.000
19
36
526.8