Operating Instruction

EDGE FCR 3 Operating Instruction
Rev. C, 2019-09-10 Release Page 43 of 64
© MYNXG Product GmbH, 2019. All rights reserved
6 Electrical Standards and Specifications
IMPORTANT NOTICE
Absolute Maximum Ratings are those values within damages on the
device will not occur. Any operation outside these maximum ratings may
cause damages on the device. Recommended Operating Conditions are
conditions under which operations of the device are intended to be
functional. Typically values corresponds to temperature TJ = 25
°
C.
Unless otherwise stated, the following conditions apply for supply
voltage: Vin = 24 VDC.
6.1 Absolute Maximum Ratings
Exposure to absolute maximum rating conditions for permanent periods of time might also
affect reliability. Each condition is applied with all other values kept within the recommended
operating conditions (Table 4).
Table 4: Absolute Maximum Ratings.
Symbol
Parameter
Min.
Max.
Unit
Vin
Input Voltage on the DC Jack or on the PCB terminal
blocks
16
42
V
Tstg
Storage Temperature
-40
85
°
C
6.2 Recommended Operating Conditions
The recommended operating conditions specify the values under which the device
operationally meets the specifications (Table 5). The power supply should be at least 20W at
24VDC.