IEX-16L CONFIGURATION
Configuring the IEX-16L- with the exception of locking/unlocking- is possible from any myMix device on the network, or
from a myMix unit that is connected to the CONFIG port of the IEX-16L. Note that the CONFIG port does not support any
audio transmission. All settings in the IEX-16L (channel mode, naming, and gain) are stored within the actual unit, so if the
unit is power cycled it will restore the settings to their last configuration.
Access, Lock, Factory Default
To show a list of all available remote devices on the myMix network, go to SETTINGS on any myMix on the network, scroll
to Remote Devices and press the Encoder button. Each IEX-16L is shown with its name, MAC address, and current
firmware version. RENAME, allows you to rename the IEX-16L as it should appear on the network.
The LOCK/UNLOCK function is only available when connected to the CONFIG port. It is not possible to lock or unlock from
a myMix over the network connection. When locked the IEX-16L can‘t be edited. Factory Defaults clear all current settings
in the IEX-16L and puts all input channels to dual mono.
Input Mode
Selecting an IEX-16L from the list and pressing the myMix encoder button opens the configuration page of the IEX-16L.
The softkey Mode toggles between the different input configurations. Dual Mono configures two independent mono
channels, while Stereo assigns physically adjacent channels to a stereo pair where the odd channel number is left and the
even channel number is right. Stereo pairs take the name of the odd numbered (or left) channel. Disable: disables an input
pair from being active on the network. This function is useful when only a few inputs of the IEX-16L are used, or the overall
network channel count has to be limited to 16 and other input sources are used as well.
Note: when the IEX16L has been locked, it is still possible to look at the configuration from every myMix on the network, but
not to change anything. Attempting to edit a locked IEX16L will trigger the message: „Locked“.