Installation guide

Setting and Modifying Controller Options
4-22 GAM Client v3.00 and WSAM Users Manual
Initial Delay. Number of seconds between physical device start-ups.
Sequential Delay. Number of seconds between consecutive device
spin-up cycles.
Change any of the following SCSI Parameters (note that Transfer
Speed is read only):
Channel for this controller
Whether the controller will handle data at 8-bit or 16-bit transfers
Maximum data transfer rate of the disk side channels. Speeds are
Asynchronous, 5 MHz, 8 MHz, 10 MHz, 20 MHz, and 40 MHz
(LVD only).
SCSI Tag Queuing. Enable in order to queue up commands to be
executed by the target.
Enable (by checking) or disable (by unchecking) the following
Clustering Parameter:
Clustering. Under Windows 2000 or Windows NT 4.0, allows
redundancy among controllers in various servers. If a controller or
server fails, another controller can take over the disk drives and disk
arrays that were formerly handled by the failed controller. This
mechanism imparts a fault tolerance among controllers and
servers.
Change the following Clustering Parameter:
Controller Host ID. Change if you want to set this controllers
target ID to something other than 7.
Click the OK button to accept the changes, or the Cancel button to discard