Installation guide
Manual No. 771961 A-1
Appendix A
Error Codes
Overview
Global Array Manager provides information about drive and controller
failures, as well as maintaining an event log. Global Array Manager
classifies the events it records into five severity levels described in
Table A-1.
Table A-1. Severity Level Priorities and Descriptions
Critical (Level 0)
388 Controller is dead. System is disconnecting from this controller
391 Controller is gone. System is disconnecting from this controller.
395 Controller is gone. System is disconnecting from this controller.
398 Controller is gone. System is disconnecting from this controller.
414 ECC error occured.
415 Hard ECC error occured.
418 Battery Backup Unit is dead.
Severity Type Description
0 Critical Controller failure.
1 Serious The failure of a major component within the array
enclosure. For example, a power supply, fan or
physical drive.
2 Error A consistency check fails, or a rebuild on a drive
stopped because of errors.
3 Warning Global Array Manager has failed to kill a drive, or
failed to start a rebuild.
4 Informational Messages such as sign-ons and system
startups. When a consistency check or a rebuild
has finished, for example, or a physical drive has
been put on standby.