Installation guide

Monitoring
Manual No. 771961 5-53
New Mylex PCI and All Mylex External RAID Controllers
Figure 5-54 shows the Intelligent BBU window for new Mylex PCI
1
and all
External RAID Controllers:
Figure 5-54. Intelligent BBU - New PCI and All External Controllers
The Intelligent Battery Backup Unit (BBU) dialog box is used to monitor
and charge or recharge the backup battery pack on the controller. This
battery pack maintains the controller's data in RAM in case AC power is lost
to the disk storage system. When a new battery is needed, the BBU dialog
indicates this by showing the battery can no longer take or hold a charge.
This dialog box is also used after an old battery pack is replaced with a new
one. The new battery must be fully discharged before it can be charged up.
Prior to beginning normal operations, Mylex recommends that you condition
the battery for maximum longevity. See Conditioning the Battery on page
5-55.
Power Levels
The Power Levels area of the Intelligent Battery Backup Unit dialog box
contains the following:
Low Power Threshold. A preset or modifiable power level, expressed
as hours or minutes of charge, used to trigger an alarm when the battery
1. AcceleRAID 352, eXtremeRAID 2000, eXtremeRAID 3000