Installation guide
Enclosure Monitoring and Management
5-28 GAM Client v3.00 and WSAM User’s Manual
way
• OK - The UPS is optimal. Three additional items are displayed with
this state: AC Pwr - the UPS is reporting an AC power failure; DC
Pwr - the UPS is reporting a DC power failure; Low Bat - the UPS
can power the system for only 2 to 5 more minutes.
• Failed - The UPS is installed, but has failed
• Error status for troubleshooting purposes. Error status for an enclosure
is reported in a format similar to the following example:
0 Addressing 25 02:03 04:05
• 0 is the error number
• Addressing is the error type
• 25 is the ALPA (Arbitrated Loop - Port Address) of the drive in
question
• 02:03 is the first known channel and target to which the ALPA is
mapped
• 04:05 is the second known channel and target to which the ALPA is
mapped
• An information field (may need to scroll, not visible in Figure 5-27
above), which contains most of the items listed on the Information
page, for easier cross-reference
Click the Close button to close the dialog box.