Installation guide

Monitoring
Manual No. 771961 5-27
The speed of the fans in the enclosure (not shown for SAF-TE
enclosures). Each fan is designated with a number. The values are:
Absent - The fan is not installed, or has failed in an undetectable way
OK - The fan is optimal. Fan speed is shown as either Stopped, Low,
or High.
Failed - The fan is installed, but has failed
The status of the power supplies in the enclosure. Each power supply is
designated with a number. The status values are:
Absent - The power supply is not installed, or has failed in an
undetectable way
OK - The power supply is optimal
Failed - The power supply is installed, but has failed
The status of the temperature sensors in the enclosure. Each
temperature sensor is designated with a number. The status values are:
Absent - The temperature sensor is not installed, or has failed in an
undetectable way
OK - The temperature sensor is optimal. Two additional items are
displayed with this state: Celsius Temperature (range for SES is -19º
to +235º; range for SAF-TE is -10º to +245º); Over Temperature
Warning (OT).
Failed - The temperature sensor is installed, but has failed
The status of the alarms or speakers in the enclosure. Each alarm is
designated with a number. The status values are:
Absent - The alarm is not installed, or has failed in an undetectable
way
OK - The alarm is optimal. One additional item is displayed with
this state: ON - the alarm is currently on or sounding.
Failed - The alarm is installed, but has failed
The status of the enclosures connection to one or more
Uninterruptable Power Supplies (UPS). Each UPS is designated with a
number. The status values are:
Absent - The UPS is not installed, or has failed in an undetectable