Installation guide
Enclosure Monitoring and Management
5-26 GAM Client v3.00 and WSAM User’s Manual
Details Page
Figure 5-27. SES Enclosure Information: Details Page
Enclosure Information Details page (Figure 5-27) displays the following
about the currently-available Fibre enclosures:
• The status of each enclosure, identified by an icon and an enclosure
number, as well as one of the following expressed in text:
• OK - All components are optimal
• Critical - Some component has failed; one more failure may result in
data loss
• Failed - A failure has occurred that may result in data loss
• The access status of each enclosure, which indicates the controller’s
ability to communicate with the enclosure. The status values are:
• OK - Access is optimal
• Critical - Only one access path remains of the several that were
detected previously. If the last access path is lost, the controller will
take steps to protect the data.
• Lost - The enclosure is unreachable by the controller. Any failures in
the enclosure while this state exists will not be sensed by the
controller.