Controller Monitoring
5-6 GAM Client v3.00 and WSAM User’s Manual
All RAID Controllers Except eXtremeRAID 3000 and
External Fibre-to-Fibre
Figure 5-5. Controller View Window - “Non-Fibre” RAID Controller
The Controller View window (Figure 5-5), displays the following
information about the controller currently selected in the controller selection
box:
The number of channels on this controller, each channel depicted as a
tower
The physical devices present on each channel, specifying the target ID,
capacity of the device, device type, and device status
The logical drives configured on the controller, specifying the logical
drive number, capacity of the logical drive, configured RAID level, and
logical drive status
Note
Dual active controllers (External RAID Controller
operation) will show at target ID 6 AND 7 in each
channel column. This only appears if the selected
controller is operating in duplex.